Lookup-table-based inverse model for human skin reflectance spectroscopy: two-layered Monte Carlo simulations and experiments
X Zhong, X Wen, D Zhu - Optics express, 2014 - opg.optica.org
Fiber reflectance spectroscopy is a non-invasive method for diagnosing skin diseases or
evaluating aesthetic efficacy, but it is dependent on the inverse model validity. In this work, a …
evaluating aesthetic efficacy, but it is dependent on the inverse model validity. In this work, a …
White light oblique incidence reflectometer for measuring absorption and reduced scattering spectra of tissue-like turbid media
G Marquez, LV Wang - Optics Express, 1997 - opg.optica.org
We designed a quick and inexpensive system for spectral measurements of optical
properties including absorption coefficient and reduced scattering coefficient. The system …
properties including absorption coefficient and reduced scattering coefficient. The system …
Micromachined Fiber Optical Sensor for In Vivo Measurement of Optical Properties of Human Skin
A Garcia-Uribe, KC Balareddy, J Zou… - IEEE Sensors …, 2008 - ieeexplore.ieee.org
In this paper, we present the design, fabrication, and testing of a new micromachined fiber
optic sensor probe to conduct oblique incidence diffuse reflectance spectrometry (OIDRS) …
optic sensor probe to conduct oblique incidence diffuse reflectance spectrometry (OIDRS) …
Application of spectral derivative data in visible and near-infrared spectroscopy
The use of the spectral derivative method in visible and near-infrared optical spectroscopy is
presented, whereby instead of using discrete measurements around several wavelengths …
presented, whereby instead of using discrete measurements around several wavelengths …
A strategy for quantitative spectral imaging of tissue absorption and scattering using light emitting diodes and photodiodes
A diffuse reflectance spectroscopy system was modified as a step towards miniaturization
and spectral imaging of tissue absorption and scattering. The modified system uses a …
and spectral imaging of tissue absorption and scattering. The modified system uses a …
Design and characterization of a novel multimodal fiber-optic probe and spectroscopy system for skin cancer applications
M Sharma, E Marple, J Reichenberg… - Review of Scientific …, 2014 - pubs.aip.org
The design and characterization of an instrument combining Raman, fluorescence, and
reflectance spectroscopic modalities is presented. Instrument development has targeted skin …
reflectance spectroscopic modalities is presented. Instrument development has targeted skin …
Measurement of the local optical properties of turbid media by differential path-length spectroscopy
A Amelink, HJCM Sterenborg - Applied optics, 2004 - opg.optica.org
We report on the development of an optical-fiber-based diagnostic tool with which to
determine the local optical properties of a turbid medium. By using a single fiber in contact …
determine the local optical properties of a turbid medium. By using a single fiber in contact …
A low-cost, portable, and quantitative spectral imaging system for application to biological tissues
The ability of diffuse reflectance spectroscopy to extract quantitative biological composition
of tissues has been used to discern tissue types in both pre-clinical and clinical cancer …
of tissues has been used to discern tissue types in both pre-clinical and clinical cancer …
Accuracy limits in the determination of absolute optical properties using time‐resolved NIR spectroscopy
V Ntziachristos, B Chance - Medical physics, 2001 - Wiley Online Library
We assess typical systematic experimental errors involved in a time‐resolved measurement
as applied to NIR diffuse optical spectroscopy and investigate their effect on the …
as applied to NIR diffuse optical spectroscopy and investigate their effect on the …