MR elastography of liver at 3 Tesla: comparison of gradient-recalled echo (GRE) and spin-echo (SE) echo-planar imaging (EPI) sequences and agreement across …

C Zhan, S Kannengiesser, H Chandarana… - Abdominal …, 2019 - Springer
Purpose To compare 2D gradient-recalled echo (GRE) and 2D spin-echo (SE) echo-planar
imaging (EPI) MR elastography (MRE) for measurement of hepatic stiffness in adult patients …

Intra-patient comparison of 3D and 2D magnetic resonance elastography techniques for assessment of liver stiffness

R Catania, C Lopes Vendrami, BD Bolster… - Abdominal …, 2022 - Springer
Purpose To evaluate performance of 3D magnetic resonance elastography (MRE) using
spin-echo echo-planar imaging (seEPI) for assessment of hepatic stiffness compared with …

Magnetic resonance elastography of healthy livers at 3.0 T: Normal liver stiffness measured by SE-EPI and GRE

JS Bae, JM Lee, SJ Park, KB Lee, JK Han - European Journal of Radiology, 2018 - Elsevier
Purpose To determine the normal liver stiffness values using magnetic resonance
elastography (MRE) at 3.0 T and to compare spin-echo echo-planar imaging (SE-EPI) and …

Magnetic resonance elastography SE-EPI vs GRE sequences at 3T in a pediatric population with liver disease

JS Calle-Toro, SD Serai, EA Hartung, DJ Goldberg… - Abdominal …, 2019 - Springer
Purpose The goal of our study is to compare hepatic stiffness measures using gradient-
recalled echo (GRE) versus spin-echo echo planar imaging (SE-EPI)-based MR …

Magnetic resonance elastography of the liver: qualitative and quantitative comparison of gradient echo and spin echo echoplanar imaging sequences

M Wagner, C Besa, JB Ayache, TK Yasar… - Investigative …, 2016 - journals.lww.com
Objective The aim of this study was to compare 2-dimensional (2D) gradient recalled echo
(GRE) and 2D spin echo echoplanar imaging (SE-EPI) magnetic resonance elastography …

Spin-echo echo-planar imaging MR elastography versus gradient-echo MR elastography for assessment of liver stiffness in children and young adults suspected of …

SD Serai, JR Dillman, AT Trout - Radiology, 2017 - pubs.rsna.org
Purpose To compare two-dimensional (2D) gradient-recalled echo (GRE) and 2D spin-echo
(SE) echo-planar imaging (EPI) magnetic resonance (MR) elastography for measurement of …

Liver stiffness measurements with MR elastography: agreement and repeatability across imaging systems, field strengths, and pulse sequences

AT Trout, S Serai, AD Mahley, H Wang, Y Zhang… - Radiology, 2016 - pubs.rsna.org
Purpose To prospectively assess agreement and repeatability of magnetic resonance (MR)
elastography liver stiffness measurements across imager manufacturers, field strengths, and …

[HTML][HTML] MR elastography in patients with suspected diffuse liver disease at 1.5 T: Intraindividual comparison of gradient-recalled echo versus spin-echo echo-planar …

M Plaikner, C Kremser, H Zoller… - European Journal of …, 2021 - Elsevier
Purpose To compare liver stiffness (LS) in patients with suspected diffuse liver disease
between gradient-recalled-echo magnetic resonance elastography (GRE-MRE) and …

Application of modified spin-echo–based sequences for hepatic MR elastography: evaluation, comparison with the conventional gradient-echo sequence, and …

YK Mariappan, B Dzyubak, KJ Glaser, SK Venkatesh… - Radiology, 2017 - pubs.rsna.org
Purpose To (a) evaluate modified spin-echo (SE) magnetic resonance (MR) elastographic
sequences for acquiring MR images with improved signal-to-noise ratio (SNR) in patients in …

Magnetic resonance elastography: feasibility of liver stiffness measurements in healthy volunteers at 3 T

L Mannelli, E Godfrey, MJ Graves, AJ Patterson… - Clinical radiology, 2012 - Elsevier
AIM: To demonstrate the feasibility of obtaining liver stiffness measurements with magnetic
resonance elastography (MRE) at 3T in normal healthy volunteers using the same technique …