[HTML][HTML] Reproducibility of small animal cine and scar cardiac magnetic resonance imaging using a clinical 3.0 tesla system

R Manka, C Jahnke, T Hucko… - BMC medical …, 2013 - bmcmedimaging.biomedcentral.com
To evaluate the inter-study, inter-reader and intra-reader reproducibility of cardiac cine and
scar imaging in rats using a clinical 3.0 Tesla magnetic resonance (MR) system. Thirty-three …

Pre-clinical functional magnetic resonance imaging part II: the heart

NM Meßner, FG Zöllner, R Kalayciyan… - Zeitschrift für Medizinische …, 2014 - Elsevier
One third of all deaths worldwide in 2008 were caused by cardiovascular diseases (CVD),
and the incidence of CVD related deaths rises ever more. Thus, improved imaging …

Feasibility of functional cardiac MR imaging in mice using a clinical 3 Tesla whole body scanner

AC Bunck, MA Engelen, B Schnackenburg… - Investigative …, 2009 - journals.lww.com
Objectives: To test the feasibility of cardiac MR imaging in mice using a clinical 3 Tesla
whole body MR system for structural and functional analysis. Standard protocols for bright …

Cardiac magnetic resonance imaging in small rodents using clinical 1.5 T and 3.0 T scanners

WD Gilson, DL Kraitchman - Methods, 2007 - Elsevier
Cardiac magnetic resonance (CMR) imaging can provide noninvasive, high resolution
images of heart anatomy, viability, perfusion, and function. However, the adoption of clinical …

[HTML][HTML] Technical Aspects of in vivo Small Animal CMR Imaging

H Li, A Abaei, P Metze, S Just, Q Lu, V Rasche - Frontiers in Physics, 2020 - frontiersin.org
Cardiovascular magnetic resonance (CMR) imaging has become an accurate and versatile
imaging modality to visualize the cardiovascular system in normal or abnormal conditions. In …

Variability of mouse left ventricular function assessment by 11.7 Tesla MRI

L Vanhoutte, B Gallez, O Feron, JL Balligand… - Journal of …, 2015 - Springer
Abstract We studied intraobserver (n= 24), interobserver (n= 24) and interexperiment (n= 12)
reproducibility of left ventricular (LV) mass and volume measurements in mice using an 11.7 …

[HTML][HTML] 2099 Cardiac MRI@ 7-Tesla: initial experiments in pigs

HH Quick, F Breuckmann… - Journal of …, 2008 - jcmr-online.biomedcentral.com
Purpose The purpose of this study was to perform cardiac MRI at 7-Tesla in a pig model in
order to evaluate potential advantages and disadvantages specifically associated with …

170 In vivo cardiac magnetic resonance imaging of adult zebrafish

G Merrifield, J Mullin, L Gallagher, C Tucker, M Jansen… - 2015 - heart.bmj.com
Introduction While the embryonic zebrafish has been widely used for basic cardiac research
the adult zebrafish has been used less partly due to difficulties in evaluating the hearts …

Cardiac MR characterization of left ventricular remodeling in a swine model of infarct followed by reperfusion

J Whitaker, CM Tschabrunn, J Jang… - Journal of Magnetic …, 2018 - Wiley Online Library
Background Myocardial infarction (MI) survivors are at risk of complications including heart
failure and malignant arrhythmias. Purpose We undertook serial imaging of swine following …

[引用][C] Practical multi-mode cardiac MRI of mice and rats on a 3T clinical scanner

RJ Beyers, N Salibi, R Amin, JC Quindry… - Proc Intl Soc Mag …, 2012 - archive.ismrm.org
(ISMRM 2012) Practical Multi-Mode Cardiac MRI of Mice and Rats on a 3T Clinical Scanner
Index Search Educational About Prev Next Meeting Banner Abstract #4240 Practical Multi-Mode …