Prospective evaluation of a novel catheter equipped with mini electrodes on a 10-mm tip for cavotricuspid isthmus ablation-The efficacy of a mini electrode guided …

T Takagi, S Miyazaki, T Niida, T Kajiyama… - International Journal of …, 2017 - Elsevier
Background Clinical utility of large-tip ablation catheters for cavo-tricuspid isthmus (CTI)
ablation has been reported, however, it is limited by the impaired near-field electrogram …

[HTML][HTML] A comparison of the efficacy of voltage-directed cavotricuspid isthmus ablation using mini versus conventional electrodes

R Somani, GA Ng, NA Hobson… - The Journal of …, 2018 - ncbi.nlm.nih.gov
Cavotricuspid isthmus (CTI) ablation is a current first-line management method for typical
atrial flutter. A voltage-directed technique that systematically targets points of maximal …

[PDF][PDF] Gold-tip versus contact-sensing catheter for cavotricuspid isthmus ablation: A comparative study

EE Gül, U Boles, S Haseeb, WM Hopman… - … Kardiyol Dern Ars, 2018 - jag.journalagent.com
Objective: Radiofrequency (RF) ablation is a highly successful procedure for the
management of typical atrial flutter (AFL), an abnormal heart rhythm originating within the …

Prospective randomized comparison of 8‐mm gold‐tip, externally irrigated‐tip and 8‐mm platinum‐iridium tip catheters for cavotricuspid isthmus ablation

F Sacher, MD O'NEILL, P Jais, LL Huffer… - Journal of …, 2007 - Wiley Online Library
Introduction: Radiofrequency (RF) ablation of the cavotricuspid isthmus (CTI) can be
performed using different types of ablation catheter. Gold tip electrodes have the theoretical …

Cavotricuspid Isthmus Ablation with Large‐Tip Gold Alloy Versus Platinum‐Iridium‐Tip Electrode Catheters

A Kardos, C Foldesi, A Mihalcz… - Pacing and Clinical …, 2009 - Wiley Online Library
Background: Gold has excellent electrical conductive properties and creates deeper and
wider lesions than platinum‐iridium during radiofrequency (RF) ablation in vitro. We tested …

Cavotricuspid isthmus ablation using a catheter equipped with mini electrodes on the 8 mm tip: a prospective comparison with an 8 mm dumbbell-shaped tip catheter …

J Iwasawa, S Miyazaki, T Takagi, H Taniguchi… - Europace, 2016 - academic.oup.com
Aims The mini electrodes (ME) placed on the tip of the ablation electrode provide more
precise local signal. We evaluated whether ME catheter was effective for the ablation of …

[HTML][HTML] Local impedance and contact force guidance to predict successful cavotricuspid isthmus ablation with a zero-fluoroscopy approach

J Melero-Polo, M Cabrera-Ramos… - Frontiers in …, 2024 - frontiersin.org
Introduction A new technology capable of monitoring local impedance (LI) and contact force
(CF) has recently been developed. At the same time, there is growing concern regarding …

[HTML][HTML] Impact of tag index and local electrogram for successful first-pass cavotricuspid isthmus ablation

M Kashiwagi, A Kuroi, N Higashimoto, K Mori… - Heart Rhythm O2, 2023 - Elsevier
Background The optimal ablation index (AI) value for cavotricuspid isthmus (CTI) ablation is
unknow. Objective This study investigated the optimal AI value and whether preassessment …

Variable procedural strategies adapted to anatomical characteristics in catheter ablation of the cavotricuspid isthmus using a preoperative multidetector computed …

K Kajihara, Y Nakano, Y Hirai, H Ogi… - Journal of …, 2013 - Wiley Online Library
Variable Strategies for CTI Ablation Objectives This study aimed to investigate the
anatomical characteristics complicating cavotricuspid isthmus (CTI) ablation and the …

Cavotricuspid isthmus ablation guided by force‐time integral–A randomized study

D Asvestas, V Sousonis, G Kotsovolis… - Clinical …, 2022 - Wiley Online Library
Background Force‐time integral (FTI) is an ablation marker of lesion quality and
transmurality. A target FTI of 400 gram‐seconds (gs) has been shown to improve durability …