Direct measurement of the scattering coefficient
M Hohmann, B Lengenfelder, D Muhr… - Biomedical Optics …, 2021 - opg.optica.org
In general, the measurement of the main three optical properties (µ_a, µ_s and g) in turbid
media requires a very precise measurement of the total transmission (TT), the total reflection …
media requires a very precise measurement of the total transmission (TT), the total reflection …
Simultaneous recovery of a full set of optical properties in turbid media using incomplete P5 approximation to CW radiance
L Liu, W Wan, J Li, H Zhao, F Gao - Optics Letters, 2018 - opg.optica.org
Traditional methods for determining the optical properties of turbid media are implemented
in diffusive regimes, where the scattering coefficient μ_s and anisotropy factor g are …
in diffusive regimes, where the scattering coefficient μ_s and anisotropy factor g are …
Reconstruction of optical coefficients in turbid media using time-resolved reflectance and calibration-free instrument response functions
M Helton, MA Mycek, K Vishwanath - Biomedical Optics Express, 2022 - opg.optica.org
Measurements of time-resolved reflectance from a homogenous turbid medium can be
employed to retrieve the absolute values of its optical transport coefficients. However, the …
employed to retrieve the absolute values of its optical transport coefficients. However, the …
Estimation of optical properties of turbid media: experimental comparison of spatially and temporally resolved reflectance methods
J Falconet, A Laidevant, R Sablong, A da Silva… - Applied …, 2008 - opg.optica.org
We compare two methods for the optical characterization of turbid media. The estimates of
the absorption and reduced scattering coefficients (μ_a and μs′) by a spatially resolved …
the absorption and reduced scattering coefficients (μ_a and μs′) by a spatially resolved …
Separation of absorption and scattering properties of turbid media using relative spectrally resolved cw radiance measurements
S Grabtchak, WM Whelan - Biomedical optics express, 2012 - opg.optica.org
We present a new method for extracting the effective attenuation coefficient and the diffusion
coefficient from relative spectrally resolved cw radiance measurements using the diffusion …
coefficient from relative spectrally resolved cw radiance measurements using the diffusion …
Method for measuring absolute optical properties of turbid samples in a standard cuvette
Featured Application Quantitative and calibration free determination of the absolute optical
properties of turbid samples in a standard cuvette with milliliter scale volume. Abstract Many …
properties of turbid samples in a standard cuvette with milliliter scale volume. Abstract Many …
Absolute absorber quantification in turbid media at small source–detector separations
S Willmann, A Terenji, J Osterholz, HJ Schwarzmaier… - Applied Physics B, 2002 - Springer
The aim of our studies was to develop a method to determine the absorption coefficient of a
turbid medium in a reflection geometry with small source–detector separations. Therefore …
turbid medium in a reflection geometry with small source–detector separations. Therefore …
Estimation of optical properties by spatially resolved reflectance spectroscopy in the subdiffusive regime
P Naglič, F Pernuš, B Likar… - Journal of Biomedical …, 2016 - spiedigitallibrary.org
We propose and objectively evaluate an inverse Monte Carlo model for estimation of
absorption and reduced scattering coefficients and similarity parameter γ from spatially …
absorption and reduced scattering coefficients and similarity parameter γ from spatially …
Spectral determination of μa, μs and g from single and multiple scattering signals with one optically thick sample
P Tian, SM Mutisya, J Jin, S Zheng, JQ Lu… - Journal of Quantitative …, 2020 - Elsevier
Abstract Development of robust and easy-to-implement methods for quantitative turbidity
characterization by inherent properties of absorption and scattering can have wide …
characterization by inherent properties of absorption and scattering can have wide …
Determination of the optical properties of turbid media using relative interstitial radiance measurements: Monte Carlo study, experimental validation, and sensitivity …
LCL Chin, AE Worthington… - Journal of biomedical …, 2007 - spiedigitallibrary.org
Interstitial quantification of the optical properties of tissue is important in biomedicine for both
treatment planning of minimally invasive laser therapies and optical spectroscopic …
treatment planning of minimally invasive laser therapies and optical spectroscopic …
相关搜索
- turbid media optical properties
- radiance measurements optical properties
- full set optical properties
- subdiffusive regime optical properties
- simultaneous recovery optical properties
- reflectance spectroscopy optical properties
- sensitivity analysis optical properties
- radiance measurements turbid media
- experimental comparison optical properties
- turbid media full set
- turbid media detector separations
- turbid media simultaneous recovery
- turbid media experimental comparison
- turbid media sensitivity analysis
- spectral determination scattering signals
- experimental validation optical properties