[PDF][PDF] Evaluation of stable retentive properties of overdenture attachments

V Rutkunas, H Mizutani, H Takahashi - Stomatologija, 2005 - sbdmj.lsmuni.lt
Objectives: To evaluate fatigue of stud (ERA Overdenture (orange and white), Locator Root
(pink) and OP anchor# 4) and magnetic (Magfit EX600W) attachments by measuring …

Retention force and fatigue strength of overdenture attachment systems

DM Botega, MF Mesquita… - Journal of oral …, 2004 - Wiley Online Library
summary This study evaluated retention force and fatigue resistance of two overdenture
attachment systems. Twenty samples (O‐ring and Bar‐Clip) from two manufacturers …

Comparative study of retentive anchor systems for overdentures.

CA Svetlize… - Quintessence …, 2004 - search.ebscohost.com
Objectives: This study aimed to evaluate the retention on two or four implants of eight
resilient and nonresilient retentive anchors used in overdentures Method and materials …

Wear simulation effects on overdenture stud attachments

V Rutkunas, H Mizutani, H Takahashi… - Dental materials …, 2011 - jstage.jst.go.jp
The aim of this study was to evaluate wear effects on overdenture resilient attachments. Six
commercially available attachments were investigated: ERA orange and white (EO and EW) …

Comparative study of four retentive anchor systems for implant supported overdentures–retention force changes

S Bayer, D Steinheuser, M Grüner, L Keilig… - …, 2009 - Wiley Online Library
Objectives: Wear of attachments leads to a loss of retention and potentially reduces the
function of complete dentures. This study evaluated the retention force changes of different …

[HTML][HTML] Effect of abutment angulation in the retention and durability of three overdenture attachment systems: An in vitro study

C Aroso, AS Silva, R Ustrell, JM Mendes… - The journal of …, 2016 - ncbi.nlm.nih.gov
PURPOSE This in vitro study investigated and compared the durability and retention of three
types of attachments. MATERIALS AND METHODS Three commercially available …

[HTML][HTML] In vitro retention capacity of two overdenture attachment systems: Locator® and Equator®

N Mínguez-Tomás… - Journal of clinical and …, 2018 - ncbi.nlm.nih.gov
Background It is necessary to know the in vitro behavior of different attachment systems to
be used clinically. The evolution of retention capacity over 10 years (14,600 insertion/de …

[PDF][PDF] Retentive and stabilizing properties of stud and magnetic attachments retaining mandibular overdenture. an in vitro study

V Rutkunas, H Mizutani - Stomatol Baltic Dent Maxillofac J, 2004 - sbdmj.com
Objectives: To evaluate and compare retentive and stabilizing properties of stud (ERA
Overdenture (orange and white), Locator Root (pink) and OP anchor# 4) and magnetic …

A comparative in vitro study on the retention and stability of implant-supported overdentures.

W Sadig - Quintessence International, 2009 - search.ebscohost.com
Objectives: Implant-supported overdentures have become the treatment of choice in
restoring complete edentulism, but the number of implants required and type of connectors …

The service life of implant-retained overdenture attachment systems

MN Pigozzo, MF Mesquita, GEP Henriques… - The Journal of prosthetic …, 2009 - Elsevier
STATEMENT OF PROBLEM: Implant-retained overdentures are a treatment option for
patients who are not satisfied with conventional complete dentures. Although implant …