Clinical wear of overdenture ball attachments after 1, 3 and 8 years
O Fromentin, C Lassauzay, SA Nader… - Clinical oral implants …, 2011 - Wiley Online Library
Objectives: Implant‐supported overdentures have become the treatment of choice in
restoring complete edentulism, but the types of attachment to assure durable retention are a …
restoring complete edentulism, but the types of attachment to assure durable retention are a …
In vitro comparison of the retentive properties of ball and locator attachments for implant overdentures.
P Eren Türk, O Geckili, Y Türk… - … Journal of Oral & …, 2014 - search.ebscohost.com
Purpose: To compare the retentive properties of ball and locator attachments during 5,000
insertion-separation cycles, corresponding to approximately 4.5 years of clinical use …
insertion-separation cycles, corresponding to approximately 4.5 years of clinical use …
In vitro retention force measurement for three different attachment systems for implant-retained overdenture
KM Reda, IR El-Torky, MN El-Gendy - The Journal of Indian …, 2016 - journals.lww.com
Aim: The aim of this study is to compare the retention force of three different types of
overdenture attachment systems used in implant-retained mandibular complete …
overdenture attachment systems used in implant-retained mandibular complete …
In vitro study of the retention and mechanical fatigue behavior of four implant overdenture stud-type attachments.
O Fromentin, B Picard, B Tavernier - Practical periodontics and …, 1999 - europepmc.org
This study sought to determine the influence of mechanical fatigue on four varieties of
implant overdenture studtype attachments (Supra-Snap, O'Ring, TSIB, ZAAG) …
implant overdenture studtype attachments (Supra-Snap, O'Ring, TSIB, ZAAG) …
Retention and wear behaviors of two implant overdenture stud-type attachments at different implant angulations
JW Choi, JH Bae, CM Jeong, JB Huh - The Journal of prosthetic dentistry, 2017 - Elsevier
Statement of problem Implant angulation should be considered when selecting an
attachment. Some in vitro studies have investigated the relationship between implant …
attachment. Some in vitro studies have investigated the relationship between implant …
A systematic review and meta-analysis of the attachments used in implant-supported overdentures
SH Chaware, ST Thakkar - The Journal of Indian Prosthodontic …, 2020 - journals.lww.com
Aim: To evaluate the survival rate, tissue response, and patient satisfaction of different
attachments used in implant overdenture. Settings and Design: Systematic Review and Meta …
attachments used in implant overdenture. Settings and Design: Systematic Review and Meta …
Maximum dislodging forces of implant overdenture stud attachments.
VC Petropoulos, W Smith - International Journal of Oral & …, 2002 - search.ebscohost.com
Purpose: The aim of this study was to compare the retention and stability of the Nobel
Biocare standard ball (NBS), Nobel Biocare 2.25-mm-diameter ball (NB2), Zest Anchor (ZA) …
Biocare standard ball (NBS), Nobel Biocare 2.25-mm-diameter ball (NB2), Zest Anchor (ZA) …
[引用][C] RETENTIVE ANCHORS VERSUS MAGNETS AS ATTACHMENT SYSTEMS FOR MANDIBULAR OVERDENTURE. A 5-YEAR PROSPECTIVE RANDOMISED …
CM Cristache, C Ionescu… - Metalurgia …, 2009 - … CALEA GRIVITEI, NR 83, SECTOR 1 …
Retention of implant‐supported overdentures at different implant angulations: Comparing Locator and ball attachments
N Sultana, DW Bartlett… - Clinical oral implants …, 2017 - Wiley Online Library
Objectives To assess the effect of implant angulation on the retention of two different
attachment systems for implant‐supported overdentures after a simulated fatigue period of …
attachment systems for implant‐supported overdentures after a simulated fatigue period of …
[引用][C] Comparing the effect of different inter-implant distances on the retention of locator and ball attachments
EM Amiri, F Atri, M Khalilpour, SB Alhavaz - J Int Adv Bio &Res, 2017