Intra-tester and inter-tester reliability of post-occlusive reactive hyperaemia measurement at the hallux

A Barwick, S Lanting, V Chuter - Microvascular research, 2015 - Elsevier
Background Post-occlusive reactive hyperaemia (PORH) is a measurement of the
vasodilatory capacity of the microvasculature that is associated with cardiovascular disease …

Reproducibility of blood flow and post-occlusive reactive hyperaemia as measured by venous occlusion plethysmography

DHJ Thijssen, MWP Bleeker, P Smits… - Clinical …, 2005 - portlandpress.com
Venous occlusion plethysmography is commonly used as a tool to assess BF (blood flow)
and VR (vascular resistance) at baseline and during PORH (post-occlusive reactive …

How to assess post-occlusive reactive hyperaemia by means of laser Doppler perfusion monitoring: application of a standardised protocol to patients with peripheral …

F Morales, R Graaff, AJ Smit, S Bertuglia… - Microvascular …, 2005 - Elsevier
The standardisation of manoeuvres to perform clinically discriminative microvascular flow
reserve tests is still poorly developed, as well as the response analysis. The aim of this study …

[HTML][HTML] Reproducibility and normalization of reactive hyperemia using laser speckle contrast imaging

BR Shirazi, RJ Valentine, JA Lang - PLoS One, 2021 - journals.plos.org
Background Impaired perfusion indices signal potential microvascular dysfunction
preceding atherosclerosis and other cardiometabolic pathologies. Post-occlusive reactive …

A systematic evaluation of cutaneous microcirculation in the foot using post‐occlusive reactive hyperemia

G Balasubramanian, N Chockalingam… - …, 2021 - Wiley Online Library
Objectives Cutaneous microcirculatory impairments are associated with skin injury to the
foot. Post‐Occlusive reactive hyperemia (PORH) is one of the quick and easy methods to …

A model for post-occlusive reactive hyperemia as measured with laser-Doppler perfusion monitoring

FFM de Mul, F Morales, AJ Smit… - IEEE transactions on …, 2005 - ieeexplore.ieee.org
To facilitate the quantitative analysis of post-occlusive reactive hyperaemia (PORH),
measured with laser-Doppler perfusion monitoring (LDPM) on extremities, we present a flow …

Postocclusive reactive hyperemia in healthy volunteers and patients with peripheral vascular disease measured by three noninvasive methods

T Jarm, R Kragelj, A Liebert, P Lukasiewitz… - Oxygen Transport to …, 2003 - Springer
Postocclusive reactive hyperemia (PORH) was evaluated in three healthy volunteers and in
three patients with different etiologies and suffering from peripheral arterial occlusive …

Reproducibility and methodological issues of skin post-occlusive and thermal hyperemia assessed by single-point laser Doppler flowmetry

M Roustit, S Blaise, C Millet, JL Cracowski - Microvascular research, 2010 - Elsevier
OBJECTIVE: The primary objective of this study was to evaluate 1-week reproducibility of
post-occlusive reactive hyperemia (PORH) and local thermal hyperemia (LTH) assessed by …

Reproducibility of different laser Doppler fluximetry parameters of postocclusive reactive hyperemia in human forearm skin

GB Yvonne-Tee, AHG Rasool, AS Halim… - … of pharmacological and …, 2005 - Elsevier
Introduction: Postocclusive reactive hyperemia in forearm skin is a commonly used model for
studying microvascular reactivity function, particularly in the assessment of vascular effect of …

Post‐occlusive reactive hyperemia in patients with peripheral vascular disease

X Cheng, J Mao, X Xu, M Elmandjra… - Clinical …, 2004 - content.iospress.com
We measured tissue oxygen saturation (StO 2) changes during a post‐occlusive reactive
hyperemia (PORH) test on lower extremities of peripheral vascular disease (PVD) patients …