Retrospective correction of bias in diffusion tensor imaging arising from coil combination mode

K Sakaie, M Lowe - Magnetic resonance imaging, 2017 - Elsevier
Purpose To quantify and retrospectively correct for systematic differences in diffusion tensor
imaging (DTI) measurements due to differences in coil combination mode. Background Multi …

[HTML][HTML] Inter subject variability and reproducibility of diffusion tensor imaging within and between different imaging sessions

TV Veenith, E Carter, J Grossac, VFJ Newcombe… - PloS one, 2013 - journals.plos.org
The aim of these studies was to provide reference data on intersubject variability and
reproducibility of diffusion tensor imaging. Healthy volunteers underwent imaging on two …

Diffusion tensor imaging at low SNR: nonmonotonic behaviors of tensor contrasts

BA Landman, JAD Farrell, H Huang, JL Prince… - Magnetic resonance …, 2008 - Elsevier
Diffusion tensor imaging (DTI) provides measurements of directional diffusivities and has
been widely used to characterize changes in the tissue microarchitecture of the brain. DTI is …

Potential of a statistical approach for the standardization of multicenter diffusion tensor data: A phantom study

C Timmermans, D Smeets, J Verheyden… - Journal of Magnetic …, 2019 - Wiley Online Library
Background Diffusion tensor imaging (DTI) parameters, such as fractional anisotropy (FA),
allow examining the structural integrity of the brain. However, the true value of these …

Replicability of diffusion tensor imaging measurements of fractional anisotropy and trace in brain

A Pfefferbaum, E Adalsteinsson… - Journal of Magnetic …, 2003 - Wiley Online Library
Purpose To evaluate within‐scanner and between‐scanner reliability of fractional anisotropy
(FA) and trace (sum of the diagonal elements of the diffusion tensor) as measured by …

Effects of different field strengths, gradient directions, and acquisitions on fractional anisotropy in diffusion tensor imaging: a tract‐based spatial statistics study

Y Seo - Concepts in Magnetic Resonance Part B: Magnetic …, 2013 - Wiley Online Library
The effects of increasing acquisitions and gradient directions on fractional anisotropy (FA) at
1.5 T versus 3T were investigated using an operator‐independent methodology (tract‐based …

Reproducibility and biases in high field brain diffusion MRI: An evaluation of acquisition and analysis variables

ND Papinutto, F Maule, J Jovicich - Magnetic resonance imaging, 2013 - Elsevier
Diffusion tensor imaging (DTI) of in-vivo human brain provides insights into white matter
anatomical connectivity, but little is known about measurement difference biases and …

[HTML][HTML] Reduction of bias in the evaluation of fractional anisotropy and mean diffusivity in magnetic resonance diffusion tensor imaging using region-of-interest …

Y Seo, NK Rollins, ZJ Wang - Scientific reports, 2019 - nature.com
Accurate quantification of fractional anisotropy (FA) and mean diffusivity (MD) in MR
diffusion tensor imaging (DTI) requires adequate signal-to-noise ratio (SNR) especially in …

The influence of complex white matter architecture on the mean diffusivity in diffusion tensor MRI of the human brain

SB Vos, DK Jones, B Jeurissen, MA Viergever… - Neuroimage, 2012 - Elsevier
In diffusion tensor magnetic resonance imaging (DT-MRI), limitations concerning complex
fiber architecture (when an image voxel contains fiber populations with more than one …

[HTML][HTML] Effects of orientation and anisometry of magnetic resonance imaging acquisitions on diffusion tensor imaging and structural Connectomes

R Tudela, E Munoz-Moreno, X Lopez-Gil, G Soria - Plos one, 2017 - journals.plos.org
Diffusion-weighted imaging (DWI) quantifies water molecule diffusion within tissues and is
becoming an increasingly used technique. However, it is very challenging as correct …