Retrospective correction of bias in diffusion tensor imaging arising from coil combination mode
K Sakaie, M Lowe - Magnetic resonance imaging, 2017 - Elsevier
Purpose To quantify and retrospectively correct for systematic differences in diffusion tensor
imaging (DTI) measurements due to differences in coil combination mode. Background Multi …
imaging (DTI) measurements due to differences in coil combination mode. Background Multi …
[HTML][HTML] Inter subject variability and reproducibility of diffusion tensor imaging within and between different imaging sessions
TV Veenith, E Carter, J Grossac, VFJ Newcombe… - PloS one, 2013 - journals.plos.org
The aim of these studies was to provide reference data on intersubject variability and
reproducibility of diffusion tensor imaging. Healthy volunteers underwent imaging on two …
reproducibility of diffusion tensor imaging. Healthy volunteers underwent imaging on two …
Diffusion tensor imaging at low SNR: nonmonotonic behaviors of tensor contrasts
Diffusion tensor imaging (DTI) provides measurements of directional diffusivities and has
been widely used to characterize changes in the tissue microarchitecture of the brain. DTI is …
been widely used to characterize changes in the tissue microarchitecture of the brain. DTI is …
Potential of a statistical approach for the standardization of multicenter diffusion tensor data: A phantom study
C Timmermans, D Smeets, J Verheyden… - Journal of Magnetic …, 2019 - Wiley Online Library
Background Diffusion tensor imaging (DTI) parameters, such as fractional anisotropy (FA),
allow examining the structural integrity of the brain. However, the true value of these …
allow examining the structural integrity of the brain. However, the true value of these …
Replicability of diffusion tensor imaging measurements of fractional anisotropy and trace in brain
A Pfefferbaum, E Adalsteinsson… - Journal of Magnetic …, 2003 - Wiley Online Library
Purpose To evaluate within‐scanner and between‐scanner reliability of fractional anisotropy
(FA) and trace (sum of the diagonal elements of the diffusion tensor) as measured by …
(FA) and trace (sum of the diagonal elements of the diffusion tensor) as measured by …
Effects of different field strengths, gradient directions, and acquisitions on fractional anisotropy in diffusion tensor imaging: a tract‐based spatial statistics study
Y Seo - Concepts in Magnetic Resonance Part B: Magnetic …, 2013 - Wiley Online Library
The effects of increasing acquisitions and gradient directions on fractional anisotropy (FA) at
1.5 T versus 3T were investigated using an operator‐independent methodology (tract‐based …
1.5 T versus 3T were investigated using an operator‐independent methodology (tract‐based …
Reproducibility and biases in high field brain diffusion MRI: An evaluation of acquisition and analysis variables
ND Papinutto, F Maule, J Jovicich - Magnetic resonance imaging, 2013 - Elsevier
Diffusion tensor imaging (DTI) of in-vivo human brain provides insights into white matter
anatomical connectivity, but little is known about measurement difference biases and …
anatomical connectivity, but little is known about measurement difference biases and …
[HTML][HTML] Reduction of bias in the evaluation of fractional anisotropy and mean diffusivity in magnetic resonance diffusion tensor imaging using region-of-interest …
Y Seo, NK Rollins, ZJ Wang - Scientific reports, 2019 - nature.com
Accurate quantification of fractional anisotropy (FA) and mean diffusivity (MD) in MR
diffusion tensor imaging (DTI) requires adequate signal-to-noise ratio (SNR) especially in …
diffusion tensor imaging (DTI) requires adequate signal-to-noise ratio (SNR) especially in …
The influence of complex white matter architecture on the mean diffusivity in diffusion tensor MRI of the human brain
In diffusion tensor magnetic resonance imaging (DT-MRI), limitations concerning complex
fiber architecture (when an image voxel contains fiber populations with more than one …
fiber architecture (when an image voxel contains fiber populations with more than one …
[HTML][HTML] Effects of orientation and anisometry of magnetic resonance imaging acquisitions on diffusion tensor imaging and structural Connectomes
Diffusion-weighted imaging (DWI) quantifies water molecule diffusion within tissues and is
becoming an increasingly used technique. However, it is very challenging as correct …
becoming an increasingly used technique. However, it is very challenging as correct …