Effect of distal implant inclination on dislodging forces of different locator attachments used for mandibular overdentures: an in vitro study

MA ELsyad, RM Emera… - Journal of …, 2019 - Wiley Online Library
Purpose To evaluate the effect of distal implant inclination on axial and nonaxial retentive
forces of different Locator attachments used to retain mandibular overdentures. Materials …

Effect of Different Degrees of Mesial Implant Inclination on the Retention and Stability of Two-Implant Mandibular Overdentures Retained with Stud Attachments: An In …

MA ELsyad, OE Abo Hatem… - … Journal of Oral & …, 2018 - search.ebscohost.com
Purpose: To evaluate the effect of different degrees of mesial implant inclinations on the
retention and stability of two-implant mandibular overdentures retained with stud …

Effects of Implant Angulations and Attachment Configurations on the Retentive Forces of Locator Attachment–Retained Overdentures.

B Uludag, S Polat, V Sahin… - International Journal of …, 2014 - search.ebscohost.com
Purpose: The aim of this study was to evaluate the effects of different implant angulations
and attachment configurations on the retentive forces of locator attachment–retained …

Retention and Stability of Implant-Retained Mandibular Overdentures Using Different Types of Resilient Attachments: An In Vitro Study.

MA Elsyad, NN Agha, AA Habib - International Journal of …, 2016 - search.ebscohost.com
Purpose: The aim of this study was to evaluate and compare the retention and stability of
mandibular implant overdentures using different types of resilient attachments. Materials and …

Effect of Labial Implant Inclination on the Retention and Stability of Different Resilient Stud Attachments for Mandibular Implant Overdentures: An In Vitro Study.

MA ELsyad, RMK Emera… - International Journal of …, 2019 - search.ebscohost.com
Purpose: This study evaluated the influence of labial implant inclination on the retention and
stability of different resilient stud attachments for mandibular implant overdentures. Materials …

[HTML][HTML] Strains around distally inclined implants retaining mandibular overdentures with Locator attachments: an in vitro study

MA Elsyad, FA Setta… - The journal of advanced …, 2016 - synapse.koreamed.org
PURPOSE The aim of the present study was to evaluate, by means of strain gauge analysis,
the effect of different implant angulations on strains around two implants retaining …

Comparison of Retentive properties of two Attachment Systems in Mandibular Overdentures-An in vitro study

AA Satti - 2013 - etd.uwc.ac.za
Comparison of Retentive properties of two Attachment Systems in Mandibular Overdentures -
An in vitro study Asim Alsadig Satti Page 1 Comparison of Retentive properties of two …

Dislodgement force analysis of an overdenture attachment system

B Yilmaz, E Ozkir, WM Johnston… - The Journal of Prosthetic …, 2020 - Elsevier
Statement of problem The performance of a recently introduced overdenture attachment
system after cyclic dislodgement is not known. Purpose The purpose of this in vitro study …

Retention forces of spherical attachments as a function of implant and matrix angulation in mandibular overdentures: an in vitro study

SM Ortegón, GA Thompson, JR Agar, TD Taylor… - The Journal of prosthetic …, 2009 - Elsevier
STATEMENT OF PROBLEM: Nonparallel implants, when used to retain overdentures, may
present a restorative challenge, particularly when using attachments. Premature wear of the …

Effect of LOCATOR attachments with different retentive forces on the stability of 2-implant-retained mandibular overdenture

W Liu, X Zhang, H Qing, J Wang - The Journal of Prosthetic Dentistry, 2020 - Elsevier
Statement of problem The LOCATOR system has been widely used for 2-implant-retained
mandibular overdentures (2-MOs), but the influence of different LOCATOR attachments on …