The determination of in vivo human tissue optical properties and absolute chromophore concentrations using spatially resolved steady-state diffuse reflectance …
RMP Doornbos, R Lang, MC Aalders… - Physics in Medicine …, 1999 - iopscience.iop.org
A method is described for measuring optical properties and deriving chromophore
concentrations from diffuse reflection measurements at the surface of a turbid medium. The …
concentrations from diffuse reflection measurements at the surface of a turbid medium. The …
Empirical relationship between Kubelka–Munk and radiative transfer coefficients for extracting optical parameters of tissues in diffusive and nondiffusive regimes
A Roy, R Ramasubramaniam… - Journal of biomedical …, 2012 - spiedigitallibrary.org
Kubelka–Munk (KM) theory is a phenomenological light transport theory that provides
analytical expressions for reflectance and transmittance of diffusive substrates such as …
analytical expressions for reflectance and transmittance of diffusive substrates such as …
A strategy for quantitative spectral imaging of tissue absorption and scattering using light emitting diodes and photodiodes
A diffuse reflectance spectroscopy system was modified as a step towards miniaturization
and spectral imaging of tissue absorption and scattering. The modified system uses a …
and spectral imaging of tissue absorption and scattering. The modified system uses a …
Method for measuring changes in light absorption of highly scattering media
IJ Bigio, TM Johnson, JR Mourant - US Patent 6,381,018, 2002 - Google Patents
The noninvasive measurement of variations in absorption that are due to changes in
concentrations of biochemically relevant compounds in tissue is important in many clinical …
concentrations of biochemically relevant compounds in tissue is important in many clinical …
Diffuse-reflectance spectroscopy from 500 to 1060 nm by correction for inhomogeneously distributed absorbers
Diffuse-reflectance spectroscopy for measurement of the absorption and scattering
coefficients of biological tissue produces reliable results for wavelengths from 650 to 1050 …
coefficients of biological tissue produces reliable results for wavelengths from 650 to 1050 …
Limitations of the commonly used simplified laterally uniform optical fiber probe-tissue interface in Monte Carlo simulations of diffuse reflectance
P Naglič, F Pernuš, B Likar, M Bürmen - Biomedical optics express, 2015 - opg.optica.org
Light propagation models often simplify the interface between the optical fiber probe tip and
tissue to a laterally uniform boundary with mismatched refractive indices. Such simplification …
tissue to a laterally uniform boundary with mismatched refractive indices. Such simplification …
Evaluation of a novel noncontact spectrally and spatially resolved reflectance setup with continuously variable source-detector separation using silicone phantoms
S Andree, C Reble, J Helfmann… - … of Biomedical Optics, 2010 - spiedigitallibrary.org
We present a new variant of a noncontact, oblique incidence spatially resolved reflectance
setup. The continuously variable source detector separation enables adaptation to high and …
setup. The continuously variable source detector separation enables adaptation to high and …
Monte Carlo lookup table-based inverse model for extracting optical properties from tissue-simulating phantoms using diffuse reflectance spectroscopy
We present a Monte Carlo lookup table (MCLUT)-based inverse model for extracting optical
properties from tissue-simulating phantoms. This model is valid for close source-detector …
properties from tissue-simulating phantoms. This model is valid for close source-detector …
Spatially varying optical property reconstruction using a finite element diffusion equation approximation
KD Paulsen, H Jiang - Medical Physics, 1995 - Wiley Online Library
A finite element reconstruction algorithm for optical data based on a diffusion equation
approximation is presented. A frequency domain approach is adopted and a unified …
approximation is presented. A frequency domain approach is adopted and a unified …
Influence of the phase function in generalized diffuse reflectance models: review of current formalisms and novel observations
KW Calabro, IJ Bigio - Journal of biomedical optics, 2014 - spiedigitallibrary.org
Diffuse reflectance spectroscopy, which has been demonstrated as a noninvasive diagnostic
technique, relies on quantitative models for extracting optical property values from turbid …
technique, relies on quantitative models for extracting optical property values from turbid …