The determination of in vivo human tissue optical properties and absolute chromophore concentrations using spatially resolved steady-state diffuse reflectance …

RMP Doornbos, R Lang, MC Aalders… - Physics in Medicine …, 1999 - iopscience.iop.org
A method is described for measuring optical properties and deriving chromophore
concentrations from diffuse reflection measurements at the surface of a turbid medium. The …

Empirical relationship between Kubelka–Munk and radiative transfer coefficients for extracting optical parameters of tissues in diffusive and nondiffusive regimes

A Roy, R Ramasubramaniam… - Journal of biomedical …, 2012 - spiedigitallibrary.org
Kubelka–Munk (KM) theory is a phenomenological light transport theory that provides
analytical expressions for reflectance and transmittance of diffusive substrates such as …

A strategy for quantitative spectral imaging of tissue absorption and scattering using light emitting diodes and photodiodes

JY Lo, B Yu, HL Fu, JE Bender, GM Palmer… - Optics express, 2009 - opg.optica.org
A diffuse reflectance spectroscopy system was modified as a step towards miniaturization
and spectral imaging of tissue absorption and scattering. The modified system uses a …

Method for measuring changes in light absorption of highly scattering media

IJ Bigio, TM Johnson, JR Mourant - US Patent 6,381,018, 2002 - Google Patents
The noninvasive measurement of variations in absorption that are due to changes in
concentrations of biochemically relevant compounds in tissue is important in many clinical …

Diffuse-reflectance spectroscopy from 500 to 1060 nm by correction for inhomogeneously distributed absorbers

RLP Van Veen, W Verkruysse, H Sterenborg - Optics letters, 2002 - opg.optica.org
Diffuse-reflectance spectroscopy for measurement of the absorption and scattering
coefficients of biological tissue produces reliable results for wavelengths from 650 to 1050 …

Limitations of the commonly used simplified laterally uniform optical fiber probe-tissue interface in Monte Carlo simulations of diffuse reflectance

P Naglič, F Pernuš, B Likar, M Bürmen - Biomedical optics express, 2015 - opg.optica.org
Light propagation models often simplify the interface between the optical fiber probe tip and
tissue to a laterally uniform boundary with mismatched refractive indices. Such simplification …

Evaluation of a novel noncontact spectrally and spatially resolved reflectance setup with continuously variable source-detector separation using silicone phantoms

S Andree, C Reble, J Helfmann… - … of Biomedical Optics, 2010 - spiedigitallibrary.org
We present a new variant of a noncontact, oblique incidence spatially resolved reflectance
setup. The continuously variable source detector separation enables adaptation to high and …

Monte Carlo lookup table-based inverse model for extracting optical properties from tissue-simulating phantoms using diffuse reflectance spectroscopy

R Hennessy, SL Lim, MK Markey… - Journal of biomedical …, 2013 - spiedigitallibrary.org
We present a Monte Carlo lookup table (MCLUT)-based inverse model for extracting optical
properties from tissue-simulating phantoms. This model is valid for close source-detector …

Spatially varying optical property reconstruction using a finite element diffusion equation approximation

KD Paulsen, H Jiang - Medical Physics, 1995 - Wiley Online Library
A finite element reconstruction algorithm for optical data based on a diffusion equation
approximation is presented. A frequency domain approach is adopted and a unified …

Influence of the phase function in generalized diffuse reflectance models: review of current formalisms and novel observations

KW Calabro, IJ Bigio - Journal of biomedical optics, 2014 - spiedigitallibrary.org
Diffuse reflectance spectroscopy, which has been demonstrated as a noninvasive diagnostic
technique, relies on quantitative models for extracting optical property values from turbid …