Personal dose equivalent conversion coefficients for photons to 1 GeV

KG Veinot, NE Hertel - Radiation protection dosimetry, 2011 - academic.oup.com
The personal dose equivalent, H p (d), is the quantity recommended by the International
Commission on Radiation Units and Measurements (ICRU) to be used as an approximation …

Personal dose equivalent conversion coefficients for electrons to 1 Ge V

KG Veinot, NE Hertel - Radiation protection dosimetry, 2012 - academic.oup.com
In a previous paper, conversion coefficients for the personal dose equivalent, H p (d), for
photons were reported. This note reports values for electrons calculated using similar …

Estimation of effective dose equivalent using individual dosemeters

AR Lakshmanan, RK Kher… - Radiation protection …, 1991 - academic.oup.com
A procedure for providing a conservative estimate of the limiting quantity, HE, the effective
dose equivalent for photons originating from the posterior side of the human body (PA …

Personal dose equivalent, Hp(d), and reference point for calibration

DT Bartlett - Radiation Protection Dosimetry, 2006 - academic.oup.com
Personal dose equivalent, Hp (d), is an interesting quantity. It is defined (1) as the dose
equivalent in soft tissue, at an appropriate depth, d, below a specified point on the body.(Soft …

Response of current photon personal dosemeters to new operational quantities

D Ekendahl, Z Čemusová, D Kurková… - Radiation Protection …, 2020 - academic.oup.com
The ICRU proposed new operational quantities, which are defined in close relation to
effective dose and absorbed dose. Most of the current personal dosemeters were designed …

Response of photon dosimeters and survey instruments to new operational quantities proposed by ICRU RC26

T Otto - Journal of Instrumentation, 2019 - iopscience.iop.org
Operational quantities in radiation protection are defined as conservative estimates of the
protection quantities, which are generally not accessible to measurement. Radiation …

A Modified Design of Photon Personal Dosemeter to Measure the ICRU Personal Monitoring Quantity Hp(10)

DT Bartlett, JD Hessey, PH Burgess… - Radiation protection …, 1993 - academic.oup.com
A modified design of dosemeter has been developed to measure the personal dose
equivalent at 10 mm, Hp (10) for photon radiations. By means of a combination filter …

On the current status of an ISO working document on the calibration and type testing of radiation protection dosemeters for photons

HM Kramer, J Böhm, WJ Iles… - Radiation Protection …, 1994 - academic.oup.com
Abstract In October 1992, Working Group 2'Reference Radiations' of ISO TC85/SC2'Nuclear
Energy/Radiation Protection'officially prepared a first draft of a document with the working …

A Chamber for Determining the Conventionally True Value of Hp(10) and H*(10) Needed by Calibration Laboratories

U Ankerhold, P Ambrosi, T Eberle - Radiation protection …, 2001 - academic.oup.com
A secondary standard chamber for photon radiation developed for measuring directly the
conventionally true value of the personal dose equivalent, Hp (10), in a slab phantom is now …

A Prototype Ionisation Chamber as a Secondary Standard for the Measurement of Personal Dose Equivalent, Hp(10), on a Slab Phantom

U Ankerhold, R Behrens… - Radiation protection …, 1999 - academic.oup.com
The construction and technical characteristics of a secondary standard chamber for
measuring the conventionally true value of the personal dose equivalent, Hp (10), on a slab …