Influence of cycle length variations on antitachycardia pacing effectiveness among ICD patients
J Jiménez-Candil, J Hernández, A Martín, J Moríñigo… - Heart Rhythm, 2013 - Elsevier
BACKGROUND: Antitachycardia pacing (ATP) fails to terminate 5% to 25% of ventricular
tachycardias (VTs) occurring in implantable cardioverter-defibrillator patients. We …
tachycardias (VTs) occurring in implantable cardioverter-defibrillator patients. We …
Antitachycardia pacing in patients with implantable cardioverter defibrillators: how many attempts are useful?
R Fries, A Heisel, G Kalweit, J Jung… - Pacing and clinical …, 1997 - Wiley Online Library
The purpose of this study was to determine the termination and acceleration rates for 1 to 6
attempts of antitachycardia pacing (ATP) delivered by ICD in order to terminate …
attempts of antitachycardia pacing (ATP) delivered by ICD in order to terminate …
The magnitude of sinus cycle length change during ventricular tachycardia is predictive of successful antitachycardia pacing
JF MacGregor, SL Wasmund, RK Pai… - Pacing and clinical …, 2006 - Wiley Online Library
Background: Despite the wide use of antitachycardia pacing (ATP) in patients with
implantable cardioverter defibrillators (ICDs), predictors of ATP success remain poorly …
implantable cardioverter defibrillators (ICDs), predictors of ATP success remain poorly …
Effectiveness of first versus successive antitachycardia pacing attempts: predictors and clinical consequences
J Jiménez-Candil, O Durán, J Núñez, L Bravo… - Journal of Interventional …, 2019 - Springer
Purpose Antitachycardia pacing (ATP) terminates the majority (but not all) of slow ventricular
tachycardias (S-VT) with a cycle length (CL)> 320 ms. Usually, several ATP therapies are …
tachycardias (S-VT) with a cycle length (CL)> 320 ms. Usually, several ATP therapies are …
What factors lead to the acceleration of ventricular tachycardia during antitachycardia pacing?—Results from over 1000 episodes
Y Fang, K Gu, B Yang, W Ju, H Chen, M Li… - Journal of …, 2018 - Wiley Online Library
Introduction Ventricular tachycardia (VT) acceleration due to antitachycardia pacing (ATP)
therapy could be often observed in patients with implantable cardioverter defibrillator (ICD) …
therapy could be often observed in patients with implantable cardioverter defibrillator (ICD) …
Effect of elevated heart rate preceding the onset of ventricular tachycardia on antitachycardia pacing effectiveness in patients with implantable cardioverter …
C Kouakam, B Lauwerier, D Klug, M Jarwe… - The American journal of …, 2003 - Elsevier
The incorporation of antitachycardia pacing (ATP) into implantable cardioverter defibrillators
(ICDs) has provided a better tolerated alternative to shocks. ATP has been shown to be …
(ICDs) has provided a better tolerated alternative to shocks. ATP has been shown to be …
Incidence and characteristics of type‐2 breaks in response to antitachycardia pacing therapy in implantable cardioverter defibrillator patients
V Sharma, PJ DeGROOT… - Journal of cardiovascular …, 2003 - Wiley Online Library
Introduction: Antitachycardia pacing (ATP) effectively treats monomorphic ventricular
tachycardia (VT). The VT may cease immediately upon ATP completion (type‐1 break), or it …
tachycardia (VT). The VT may cease immediately upon ATP completion (type‐1 break), or it …
Clinical predictors of antitachycardia pacing response in implantable cardioverter defibrillator patients
JW Harrison, A Manola, LK Kalluri… - Pacing and Clinical …, 2019 - Wiley Online Library
Background Antitachycardia pacing (ATP) provides safe and painless termination of
reentrant ventricular arrhythmias in patients with implantable cardioverter defibrillator (ICDs) …
reentrant ventricular arrhythmias in patients with implantable cardioverter defibrillator (ICDs) …
Empirical versus tested antitachycardia pacing in implantable cardioverter defibrillators: a prospective study including 200 patients
A Schaumann, F Mühlen, B Herse, BD Gonska… - Circulation, 1998 - Am Heart Assoc
Background—Implantable cardioverter-defibrillators (ICDs) reduce the risk of sudden
cardiac death. The objective of this study was to evaluate whether testing of antitachycardia …
cardiac death. The objective of this study was to evaluate whether testing of antitachycardia …
[HTML][HTML] Antitachycardia pacing success in implantable cardioverter-defibrillators by patient, device, and programming characteristics
LD Sterns, A Auricchio, EJ Schloss, D Lexcen… - Heart Rhythm, 2023 - Elsevier
Background Antitachycardia pacing (ATP) is an established implantable cardioverter-
defibrillator (ICD) therapy that terminates ventricular tachycardias (VTs) without painful ICD …
defibrillator (ICD) therapy that terminates ventricular tachycardias (VTs) without painful ICD …