Adaptive template matching of photoplethysmogram pulses to detect motion artefact
Objective: The photoplethysmography (PPG) signal, commonly used in the healthcare
settings, is easily affected by movement artefact leading to errors in the extracted heart rate …
settings, is easily affected by movement artefact leading to errors in the extracted heart rate …
Detection of motion artifact patterns in photoplethysmographic signals based on time and period domain analysis
The presence of motion artifacts in photoplethysmographic (PPG) signals is one of the major
obstacles in the extraction of reliable cardiovascular parameters in continuous monitoring …
obstacles in the extraction of reliable cardiovascular parameters in continuous monitoring …
A robust motion artifact detection algorithm for accurate detection of heart rates from photoplethysmographic signals using time–frequency spectral features
Motion and noise artifacts (MNAs) impose limits on the usability of the photoplethysmogram
(PPG), particularly in the context of ambulatory monitoring. MNAs can distort PPG, causing …
(PPG), particularly in the context of ambulatory monitoring. MNAs can distort PPG, causing …
Photoplethysmograph signal reconstruction based on a novel hybrid motion artifact detection–reduction approach. Part I: Motion and noise artifact detection
Motion and noise artifacts (MNA) are a serious obstacle in utilizing photoplethysmogram
(PPG) signals for real-time monitoring of vital signs. We present a MNA detection method …
(PPG) signals for real-time monitoring of vital signs. We present a MNA detection method …
Motion artefact reduction of the photoplethysmographic signal in pulse transit time measurement
Motion artefact is a common occurrence that contaminates photoplethysmographic (PPG)
measurements. To extract timing information from signals during artefact is challenging. PPG …
measurements. To extract timing information from signals during artefact is challenging. PPG …
Improving photoplethysmographic measurements under motion artifacts using artificial neural network for personal healthcare
Photoplethysmographic (PPG) measurements are susceptible to motion artifacts (MA) due to
movement of the peripheral body parts. In this paper, we present a new approach to identify …
movement of the peripheral body parts. In this paper, we present a new approach to identify …
Comparison of wavelet transformation and adaptive filtering in restoring artefact-induced time-related measurement
JYA Foo - Biomedical signal processing and control, 2006 - Elsevier
Photoplethysmography (PPG) can be used in time-related measurements such as heart rate
(HR) and pulse transit time (PTT) estimations in the medical fields. The accuracy of these …
(HR) and pulse transit time (PTT) estimations in the medical fields. The accuracy of these …
Estimation of respiratory rate from motion contaminated photoplethysmography signals incorporating accelerometry
Estimation of respiratory rate (RR) from photoplethysmography (PPG) signals has important
applications in the healthcare sector, from assisting doctors onwards to monitoring patients …
applications in the healthcare sector, from assisting doctors onwards to monitoring patients …
Detection of artifacts on photoplethysmography signals using random distortion testing
S Cherif, D Pastor, QT Nguyen… - 2016 38th Annual …, 2016 - ieeexplore.ieee.org
In this work, we describe a novel method based on waveform morphology for detecting
artifacts in photoplethysmography (PPG) signals and, thus, improve reliability of PPG. By …
artifacts in photoplethysmography (PPG) signals and, thus, improve reliability of PPG. By …
Parameter optimization of motion artifact canceling PPG-based heart rate sensor by means of cross validation
Photoplethysmography (PPG) is one of the simple and non-invasive heart rate (HR) sensing
methods, but when applying it to a person during exercise, the output is contaminated with …
methods, but when applying it to a person during exercise, the output is contaminated with …