Ultra high-speed swept source OCT imaging of the anterior segment of human eye at 200 kHz with adjustable imaging range

M Gora, K Karnowski, M Szkulmowski, BJ Kaluzny… - Optics …, 2009 - opg.optica.org
We present an application of in vivo anterior segment imaging of the human eye with an
ultrahigh speed swept source OCT instrument. For this purpose, a dedicated OCT system …

Anterior segment imaging with Spectral OCT system using a high-speed CMOS camera

I Grulkowski, M Gora, M Szkulmowski, I Gorczynska… - Optics express, 2009 - opg.optica.org
We describe a new ultrahigh speed Spectral OCT instrument making use of a CMOS camera
and demonstrate high quality in vivo imaging of the anterior segment of the human eye. The …

Corneal topography with high-speed swept source OCT in clinical examination

K Karnowski, BJ Kaluzny, M Szkulmowski… - Biomedical Optics …, 2011 - opg.optica.org
We present the applicability of high-speed swept source (SS) optical coherence tomography
(OCT) for quantitative evaluation of the corneal topography. A high-speed OCT device of …

High speed, long range, deep penetration swept source OCT for structural and angiographic imaging of the anterior eye

S Chen, B Potsaid, Y Li, J Lin, Y Hwang, EM Moult… - Scientific reports, 2022 - nature.com
This study reports the development of prototype swept-source optical coherence
tomography (SS-OCT) technology for imaging the anterior eye. Advances in vertical-cavity …

Anterior segment OCT

JS Asam, M Polzer, A Tafreshi, N Hirnschall… - High resolution imaging …, 2019 - Springer
OCT technology has been utilized successfully for anterior segment evaluation, offering
several clinically relevant applications. Its capabilities allow for non-contact imaging …

Real-time optical coherence tomography of the anterior segment at 1310 nm

S Radhakrishnan, AM Rollins, JE Roth… - Archives of …, 2001 - jamanetwork.com
Background Recent advances in high-speed scanning technology have enabled a new
generation of optical coherence tomographic (OCT) systems to perform imaging at video …

Ultrahigh-resolution OCT imaging of the human cornea

RM Werkmeister, S Sapeta, D Schmidl… - Biomedical optics …, 2017 - opg.optica.org
We present imaging of corneal pathologies using optical coherence tomography (OCT) with
high resolution. To this end, an ultrahigh-resolution spectral domain OCT (UHR-OCT) …

Micrometer axial resolution OCT for corneal imaging

R Yadav, KS Lee, JP Rolland, JM Zavislan… - Biomedical optics …, 2011 - opg.optica.org
An optical coherence tomography (OCT) for high axial resolution corneal imaging is
presented. The system uses 375 nm bandwidth (625 to 1000 nm) from a broadband …

Retinal, anterior segment and full eye imaging using ultrahigh speed swept source OCT with vertical-cavity surface emitting lasers

I Grulkowski, JJ Liu, B Potsaid, V Jayaraman… - Biomedical optics …, 2012 - opg.optica.org
We demonstrate swept source OCT utilizing vertical-cavity surface emitting laser (VCSEL)
technology for in vivo high speed retinal, anterior segment and full eye imaging. The MEMS …

250 kHz, 1.5 µm resolution SD-OCT for in-vivo cellular imaging of the human cornea

B Tan, Z Hosseinaee, L Han, O Kralj… - Biomedical optics …, 2018 - opg.optica.org
We present the first spectral domain optical coherence tomography (SD-OCT) system that
combines an isotropic imaging resolution of~ 1.5 µm in biological tissue with a 250 kHz …