Retention of implant‐supported overdentures at different implant angulations: Comparing Locator and ball attachments

N Sultana, DW Bartlett… - Clinical oral implants …, 2017 - Wiley Online Library
Objectives To assess the effect of implant angulation on the retention of two different
attachment systems for implant‐supported overdentures after a simulated fatigue period of …

Effect of distal implant inclination on dislodging forces of different locator attachments used for mandibular overdentures: an in vitro study

MA ELsyad, RM Emera… - Journal of …, 2019 - Wiley Online Library
Purpose To evaluate the effect of distal implant inclination on axial and nonaxial retentive
forces of different Locator attachments used to retain mandibular overdentures. Materials …

Effect of Interimplant Distance and Cyclic Loading on the Retention of Overdenture Attachments.

SS Shayegh, SMR Hakimaneh… - The Journal of …, 2017 - europepmc.org
AIM: The purpose of this in vitro study was to investigate the effect of interimplant distance
and cyclic loading on the retention of two locator attachment systems. MATERIALS AND …

Dislodgement force analysis of an overdenture attachment system

B Yilmaz, E Ozkir, WM Johnston… - The Journal of Prosthetic …, 2020 - Elsevier
Statement of problem The performance of a recently introduced overdenture attachment
system after cyclic dislodgement is not known. Purpose The purpose of this in vitro study …

The in vitro effect of different implant angulations and cyclic dislodgement on the retentive properties of an overdenture attachment system

SA Al-Ghafli, KX Michalakis, H Hirayama… - Journal of Prosthetic …, 2009 - thejpd.org
Purpose. The purpose of this in vitro study was to investigate the effect of cyclic
dislodgement on the retention of an overdenture attachment system when 2 implants were …

Maximum dislodging forces of implant overdenture stud attachments.

VC Petropoulos, W Smith - International Journal of Oral & …, 2002 - search.ebscohost.com
Purpose: The aim of this study was to compare the retention and stability of the Nobel
Biocare standard ball (NBS), Nobel Biocare 2.25-mm-diameter ball (NB2), Zest Anchor (ZA) …

Effects of interimplant distance and cyclic dislodgement on retention of LOCATOR and ball attachments: An in vitro study

R Salehi, SS Shayegh, WM Johnston… - The Journal of Prosthetic …, 2019 - Elsevier
Statement of problem Evaluation of the long-term retentive behavior of overdenture
attachments is necessary for successful treatment. Interimplant distance (IID) could affect the …

[引用][C] Comparing the effect of different inter-implant distances on the retention of locator and ball attachments

EM Amiri, F Atri, M Khalilpour, SB Alhavaz - J Int Adv Bio &Res, 2017

Effect of locator abutment height on the retentive values of pink locator attachments: An in vitro study

PKS Sia, R Masri, CF Driscoll, E Romberg - The Journal of prosthetic …, 2017 - Elsevier
Statement of problem Currently, no guidelines exist to help in the selection of Locator
abutments for implants at different heights. Purpose The purpose of this in vitro study was to …

[HTML][HTML] Comparison of three attachments in implant-tissue supported overdentures: an in vitro study

F Tabatabaian, F Alaie, K Seyedan - Journal of Dentistry (Tehran …, 2010 - ncbi.nlm.nih.gov
Objective: Retention and resistance of the implant-tissue supported overdenture may be
affected by the type of attachment. The aim of this research was to compare the retention …