Scintillator efficiency study with MeV x-rays

S Baker, K Brown, A Curtis, SS Lutz… - Hard X-Ray …, 2014 - spiedigitallibrary.org
We have investigated scintillator efficiency for MeV radiographic imaging. This paper
discusses the modeled detection efficiency and measured brightness of a number of …

Scintillators and detectors for MeV X-ray and neutron imaging

NJ Cherepy, ZM Seeley, S Hok… - Hard X-Ray …, 2020 - spiedigitallibrary.org
High energy X-rays and neutrons can provide 3-D volumetric views of large objects made of
multiple materials. Lenscoupled computed tomography using a scintillator imaged on a CCD …

Scintillator evaluation for high-energy X-ray diagnostics

SS Lutz, SA Baker - 2001 - osti.gov
This report presents results derived from a digital radiography study performed using x-rays
from a 2.3 MeV, rod-pinch diode. Detailed is a parameter study of cerium-doped lutetium …

Detector development for x-ray imaging

MA Mentzer, DA Herr, KJ Brewer… - … and Materials VII, 2010 - spiedigitallibrary.org
X-ray imaging requires unique optical detector system configuration for optimization of
image quality, resolution, and contrast ratio. A system is described whereby x-ray photons …

Performance model for high spatial resolution CsI scintillator screens coupled to CCD detectors

CM Castelli, NM Allinson - Journal of X-Ray Science and Technology, 1995 - Elsevier
A performance model for an x-ray imaging camera that is currently being developed at York
University for the recording of crystallographic diffraction patterns produced by synchrotron …

A new X-ray scintillator for digital radiography

VV Nagarkar, SV Tipnis, SR Miller… - 2001 IEEE Nuclear …, 2001 - ieeexplore.ieee.org
We report a new scintillator based on a transparent ceramic of Lu/sub 2/O/sub 3/: Eu. The
material has an extremely high density of 9.4 g/cm/sup 3/and a light output comparable to …

Structured scintillators for X-ray imaging with micrometre resolution

UL Olsen, S Schmidt, HF Poulsen, J Linnros… - Nuclear Instruments and …, 2009 - Elsevier
A 3D X-ray detector for imaging of 30–200keV photons is described. It comprises a stack of
semitransparent structured scintillators, where each scintillator is a regular array of …

Performance of an X-ray imaging detector based on a structured scintillator

O Svenonius, A Sahlholm, P Wiklund… - Nuclear Instruments and …, 2009 - Elsevier
Structured scintillator plates have been fabricated by filling thallium-doped caesium iodide
(CsI) into a silicon pore array. Their X-ray imaging properties have been characterized using …

Scintillator technology for enhanced resolution and contrast in X-ray imaging

A Sahlholm, O Svenonius, S Petersson - Nuclear Instruments and Methods …, 2011 - Elsevier
A structured scintillator has been fabricated by filling a deep pore array in silicon with
scintillating material. The pitch of the pores is significantly smaller (15.7 μm, hexagonal …

Photon-counting imaging camera for high-resolution X-ray and γ-ray applications

DJ Hall, A Holland - Journal of Instrumentation, 2011 - iopscience.iop.org
Standard X-ray imaging techniques using CCDs require the integration of thousands of X-
ray photons into a single image frame. Through the addition of a scintillating layer to the …