[HTML][HTML] How long does it take to read a mammogram? Investigating the reading time of digital breast tomosynthesis and digital mammography

GJW Partridge, I Darker, JJ James… - European Journal of …, 2024 - Elsevier
Purpose To analyse digital breast tomosynthesis (DBT) reading times in the screening
setting, compared to 2D full-field digital mammography (FFDM), and investigate the impact …

Does reader performance with digital breast tomosynthesis vary according to experience with two-dimensional mammography?

L Tucker, FJ Gilbert, SM Astley, A Dibden, A Seth… - Radiology, 2017 - pubs.rsna.org
Purpose To assess whether individual reader performance with digital breast tomosynthesis
(DBT) and two-dimensional (2D) mammography varies with number of years of experience …

Digital breast tomosynthesis and digital mammography recall and false-positive rates by time of day and reader experience

MH Bernstein, GL Baird, AP Lourenco - Radiology, 2022 - pubs.rsna.org
Background Digital breast tomosynthesis (DBT) image interpretation might be more
cognitively demanding than interpretation of digital mammography (DM) images. The time of …

A comparison of image interpretation times in full field digital mammography and digital breast tomosynthesis

S Astley, S Connor, Y Lim, C Tate… - Medical Imaging …, 2013 - spiedigitallibrary.org
Digital Breast Tomosynthesis (DBT) provides three-dimensional images of the breast that
enable radiologists to discern whether densities are due to overlapping structures or lesions …

Digital breast tomosynthesis with synthesized two-dimensional images versus full-field digital mammography for population screening: outcomes from the Verona …

F Caumo, M Zorzi, S Brunelli, G Romanucci, R Rella… - Radiology, 2018 - pubs.rsna.org
Purpose To examine the outcomes of a breast cancer screening program based on digital
breast tomosynthesis (DBT) plus synthesized two-dimensional (2D) mammography …

[HTML][HTML] Take a break: should breaks be enforced during digital breast tomosynthesis reading sessions?

GJW Partridge, AG Taib, P Phillips, JJ James… - European …, 2024 - Springer
Objectives Digital breast tomosynthesis (DBT) can improve diagnostic accuracy compared to
2D mammography, but DBT reporting is time-consuming and potentially more fatiguing …

Breast cancer screening with digital breast tomosynthesis: are initial benefits sustained?

M Bahl, S Mercaldo, PA Dang, AM McCarthy, KP Lowry… - Radiology, 2020 - pubs.rsna.org
Background Performance metrics with digital breast tomosynthesis (DBT) are based on early
experiences. There is limited research on whether the benefits of DBT are sustained …

A randomised trial of screening with digital breast tomosynthesis plus conventional digital 2D mammography versus 2D mammography alone in younger higher risk …

AJ Maxwell, M Michell, YY Lim, SM Astley… - European Journal of …, 2017 - Elsevier
Introduction Digital breast tomosynthesis (DBT) has been shown to increase invasive cancer
detection rates at screening compared to full field digital (2D) mammography alone, and …

The effect of the addition of tomosynthesis to digital mammography on reader recall rate and reader confidence in the UK prevalent screening round

N Upadhyay, N Soneji, V Stewart, G Ralleigh - Clinical Radiology, 2018 - Elsevier
Aim To compare reader recall rate and confidence associated with recall decisions for digital
mammography (DM) alone with DM plus digital breast tomosynthesis (DBT) in the prevalent …

Impact on the recall rate of digital breast tomosynthesis as an adjunct to digital mammography in the screening setting. A double reading experience and review of the …

LA Carbonaro, G Di Leo, P Clauser, RM Trimboli… - European journal of …, 2016 - Elsevier
Objectives To estimate the impact on recall rate (RR) of digital breast tomosynthesis (DBT)
associated with digital mammography (DM+ DBT), compared to DM alone, evaluate the …