Comparability of point-of-care whole-blood electrolyte and substrate testing using a Stat Profile Critical Care Xpress analyzer and standard laboratory methods
Z Flegar-Meštrić, S Perkov - Clinical Chemistry and Laboratory …, 2006 - degruyter.com
Background: Rapid technological progress in point-of-care testing allows the measurement
of multiple analytes in whole-blood samples. The present study evaluated biosensor-based …
of multiple analytes in whole-blood samples. The present study evaluated biosensor-based …
Management of electrolyte disorders: also the method matters!
JR Delanghe - Acta Clinica Belgica, 2019 - Taylor & Francis
Introduction: For the last few decades, electrolyte determinations in plasma or serum are
carried out by reliable potentiometric methods. In recent years, a marked technical evolution …
carried out by reliable potentiometric methods. In recent years, a marked technical evolution …
Discrepancies between sodium concentrations measured by the Kodak Ektachem 700 and by dilutional and direct ion-selective electrode analyzers
JA Stone, JR Moriguchi, DR Notto, PE Murphy… - Clinical …, 1992 - academic.oup.com
We have identified rare (approximately 0.2% of all samples), but clinically significant,
discrepancies between serum or plasma sodium concentrations measured with the Kodak …
discrepancies between serum or plasma sodium concentrations measured with the Kodak …
Successful performance of laboratory investigations with blood glucose meters employing a dynamic electrochemistry-based correction algorithm is dependent on …
F Demircik, D Klonoff, PB Musholt… - Diabetes Technology …, 2016 - liebertpub.com
Background: Devices employing electrochemistry-based correction algorithms (EBCAs) are
optimized for patient use and require special handling procedures when tested in the …
optimized for patient use and require special handling procedures when tested in the …
Improving measurement uncertainty of plasma electrolytes: a complex but not impossible task
S Pasqualetti, M Chibireva, F Borrillo… - Clinical Chemistry and …, 2021 - degruyter.com
Blood electrolyte concentrations are tightly controlled by homeostatic mechanisms, with a
very low intraindividual biological variability [1]. To be clinically useful, measurement results …
very low intraindividual biological variability [1]. To be clinically useful, measurement results …
Evaluation of the Konelab 20XT clinical chemistry analyzer
N Stojanović, D Rogić… - Clinical Chemistry and …, 2005 - degruyter.com
Abstract The Konelab 20XT (Thermo Electron Oy, Finland) is a clinical chemistry analyzer for
colorimetric, immunoturbidimetric and ion-selective electrode measurements. The aim of our …
colorimetric, immunoturbidimetric and ion-selective electrode measurements. The aim of our …
Discrepancies in electrolyte measurements by direct and indirect ion selective electrodes due to interferences by proteins and lipids
P Chopra, SK Datta - Journal of Laboratory Physicians, 2020 - thieme-connect.com
Objectives We aim to report the simultaneous effect of different protein and lipid
concentrations on sodium (Na+) and potassium (K+) measurement by direct and indirect ion …
concentrations on sodium (Na+) and potassium (K+) measurement by direct and indirect ion …
[PDF][PDF] A direct ion-selective electrode analyzer (NOVA 11+ 11) evaluated for determining Li in serum.
L Decaprio, N Hardister, D MacMillan, R Welch… - Clinical chemistry, 1987 - Citeseer
(NOVA Biomedical, Waltham, MA 02254-9141) is one of the first commercially available
direct (nondiluting) ion-selective electrode analyzers for measuring sodium, potassium, and …
direct (nondiluting) ion-selective electrode analyzers for measuring sodium, potassium, and …
The need for protein containing quality control materials for blood pH and electrolyte analyzers
B Maas, R Sprokholt, A Maas… - … Journal of Clinical and …, 1996 - Taylor & Francis
In clinical chemistry quality control refers to monitoring of precision and accuracy of the
performance of analytical methods. Calibration solutions and (matrixed) control solutions are …
performance of analytical methods. Calibration solutions and (matrixed) control solutions are …
Stability of BUN and creatinine determinations on the Siemens Advia 1800 analyzer
J Qin, H Wang, A Rets, S Harari… - Journal of clinical …, 2013 - Wiley Online Library
Background Serum creatinine values of patients tend to change as a result of the use of
different blanks used for creatinine determinations on the Advia 1650. After upgrading the …
different blanks used for creatinine determinations on the Advia 1650. After upgrading the …