Analytical Performance Verification of the Beckman Coulter AU5800 Clinical Chemistry Analyser Against Recognized Quality Specifications Reveals Relevance of …

B Glibert, V Bourleaux, R Peeters, T Reynolds… - Clinical …, 2016 - europepmc.org
Background Analytical performance of 24 Beckman-Coulter AU 5800 methods was verified
against recognized quality goals and manufacturer's expected imprecision and bias …

Ektachem slides for direct potentiometric determination of sodium in plasma: Effect of natremia, blood ph, and type of electrolyte reference fluid on concordance with …

A Boeyckens, J Schots, H Vandenplas… - Clinical …, 1992 - academic.oup.com
With electrolyte reference fluid (ERF) 00, results from Kodak Ektachem slides for the direct
potentiometric assay of sodium in plasma were significantly correlated with results from …

Enzymatic determination of sodium, potassium, and chloride in abnormal (hemolyzed, icteric, lipemic, paraproteinemic, or uremic) serum samples compared with …

W Hübl, R Wejbora, I Shafti-Keramat, A Haider… - Clinical …, 1994 - academic.oup.com
We evaluated the effect of hemolysis, icteric discoloration, lipemia, paraproteinemia, and
uremia on enzymatic methods for determining sodium, potassium, and chloride, according to …

Stability of plasma electrolytes in Barricor and PST II tubes under different storage conditions

LA Bautista Balbás, M Segovia Amaro… - Biochemia …, 2017 - hrcak.srce.hr
Sažetak Introduction: Sample stability can be influenced by many different factors;
evaporation and leakage from residual cells are the most relevant factors for electrolytes …

Reliability of IL Monarch ion-selective electrode module for sodium, potassium, and chloride measurements.

E Guagnellini, G Spagliardi, G Bernardi… - Clinical …, 1988 - academic.oup.com
We evaluated the IL Monarch random-access centrifugal analyzer for measurement of Na+,
K+, and Cl-by an indirect potentiometric method. For different concentrations of control …

Errors in the measurement of serum electrolytes

GS Thompson, ES Jones - Journal of Clinical Pathology, 1965 - jcp.bmj.com
When compared with results obtained by the authors in a department of medicine, the
values obtained by three hospital laboratories for sodium, potassium, and chloride in normal …

Evaluation of the clinical chemistry analyser Olympus AU400

E Lasnier, N Mario, MC Boque, SN You… - 2000 - degruyter.com
Abstract The Olympus AU400 analyser (Olympus, Tokyo, Japan) is an automated chemistry
instrument for turbidimetric, spectrophotometric and ion selective electrode measurements …

Relationship of the absolute difference between direct and indirect ion selective electrode measurement of serum sodium and the total protein concentration

BJ Jones, PJ Twomey - Journal of clinical pathology, 2008 - jcp.bmj.com
Aim: To derive the relationship for the difference between direct and indirect ion selective
electrode measurements of serum sodium and the total protein concentration. Methods …

[HTML][HTML] Delay in specimen processing-major source of preanalytical variation in serum electrolytes

A Baruah, P Goyal, S Sinha, KL Ramesh… - Journal of Clinical and …, 2014 - ncbi.nlm.nih.gov
Objective: To evaluate the stability of electrolytes in serum samples due to delay in analysis
in a tertiary care government hospital in India, and the maximum time delay acceptable …

Effect of low serum total protein on sodium and potassium measurement by ion-selective electrodes in critically ill patients

E Chow, N Fox, R Gama - British journal of biomedical science, 2008 - Taylor & Francis
Hypoproteinaemia may lead to spuriously high electrolyte values using indirect ion-selective