Statistical analysis of heart rate and heart rate variability monitoring through the use of smart phone cameras

JB Bolkhovsky, CG Scully… - 2012 Annual International …, 2012 - ieeexplore.ieee.org
Video recordings of finger tips made using a smartphone camera contain a pulsatile
component caused by the cardiac pulse equivalent to that present in a …

Validation of a new heart rate measurement algorithm for fingertip recording of video signals with smartphones

N Koenig, A Seeck, J Eckstein, A Mainka… - Telemedicine and e …, 2016 - liebertpub.com
Introduction: This study investigates the accuracy of a heart rate (HR) measurement
algorithm applied to a pulse wave. This was based on video signals recorded with a …

[HTML][HTML] Measurement of heart rate variability using off-the-shelf smart phones

RY Huang, LR Dung - Biomedical engineering online, 2016 - Springer
Background The cardiac parameters, such as heart rate (HR) and heart rate variability
(HRV), are very important physiological data for daily healthcare. Recently, the camera …

Validation of heart rate extraction using video imaging on a built-in camera system of a smartphone

S Kwon, H Kim, KS Park - … of the IEEE engineering in medicine …, 2012 - ieeexplore.ieee.org
As a smartphone is becoming very popular and its performance is being improved fast, a
smartphone shows its potential as a low-cost physiological measurement solution which is …

Prolonged telemetric monitoring of heart rate variability using wireless intelligent sensors and a mobile gateway

E Jovanov, A O'Donnel, A Morgan… - Proceedings of the …, 2002 - ieeexplore.ieee.org
Mobile health monitors allow patients to leave the hospital and engage in normal activity,
uploading physiological data only periodically. Most existing system use fixed gateways to …

Accuracy of heart rate variability estimation by photoplethysmography using an smartphone: Processing optimization and fiducial point selection

V Ferrer-Mileo, F Guede-Fernandez… - 2015 37th Annual …, 2015 - ieeexplore.ieee.org
This work compares several fiducial points to detect the arrival of a new pulse in a
photoplethysmographic signal using the built-in camera of smartphones or a …

Ultra short term analysis of heart rate variability using normal sinus rhythm and atrial fibrillation ECG data

L Salahuddin, MG Jeong, D Kim - 2007 9th International …, 2007 - ieeexplore.ieee.org
Heart rate variability (HRV) analysis is well established as a quantitative predictor of clinical
cardiac events. To provide reliable assessment of HRV in mobile settings, short duration …

Real time heart rate variability assessment from Android smartphone camera photoplethysmography: Postural and device influences

F Guede-Fernández, V Ferrer-Mileo… - 2015 37th Annual …, 2015 - ieeexplore.ieee.org
The aim of this paper is to present a smartphone based system for real-time pulse-to-pulse
(PP) interval time series acquisition by frame-to-frame camera image processing. The …

A novel method to detect heart beat rate using a mobile phone

P Pelegris, K Banitsas, T Orbach… - … conference of the IEEE …, 2010 - ieeexplore.ieee.org
Heart Beat Rate calculation has traditionally been conducted using specialized hardware
most commonly in the form of pulse oximeters or Electrocardiogram devices. Even though …

Improvements in remote video based estimation of heart rate variability using the Welch FFT method

M Fukunishi, D Mcduff, N Tsumura - Artificial Life and Robotics, 2018 - Springer
Non-contact heart rate and heart rate variability measurements have applications in
healthcare and affective computing. Recently, a system utilizing a five-band camera …