Implantable bladder volume sensor based on resistor ladder network composed of conductive hydrogel composite
MK Kim, H Kim, YS Jung, KMA Adem… - 2017 39th annual …, 2017 - ieeexplore.ieee.org
An accurate bladder volume monitoring system is a critical component in diagnosis and
treatment of urological disorders. Here, we report an implantable bladder volume sensor …
treatment of urological disorders. Here, we report an implantable bladder volume sensor …
Polypyrrole/agarose hydrogel-based bladder volume sensor with a resistor ladder structure
MK Kim, S Lee, I Yoon, G Kook, YS Jung, SSM Bawazir… - Sensors, 2018 - mdpi.com
Chronic monitoring of bladder activity and urine volume is essential for patients suffering
from urinary dysfunctions. However, due to the anatomy and dynamics of the bladder …
from urinary dysfunctions. However, due to the anatomy and dynamics of the bladder …
Design and fabrication of implantable pressure sensing resistor sensor for human bladder monitoring system
J Kim, B Choi - Microsystem technologies, 2011 - Springer
Many aging people and patients have difficulties in bladder control. Recent methods have
been studied for non-invasive measuring for bladder information. It must be improved to a …
been studied for non-invasive measuring for bladder information. It must be improved to a …
[HTML][HTML] Implantable bladder sensors: a methodological review
The loss of urinary bladder control/sensation, also known as urinary incontinence (UI), is a
common clinical problem in autistic children, diabetics, and the elderly. UI not only causes …
common clinical problem in autistic children, diabetics, and the elderly. UI not only causes …
A wireless bladder volume monitoring system using a flexible capacitance-based sensor
A wireless sensor system has been prototyped to monitor bladder volume in a small animal.
The capacitance-based sensor was laser-micromachined from a polyimide film to form an …
The capacitance-based sensor was laser-micromachined from a polyimide film to form an …
An in vivo MEMS sensor system for percutaneous measurement of urinary bladder
I Clausen, LGW Tvedt, A Hellandsvik… - 2017 39th Annual …, 2017 - ieeexplore.ieee.org
An in vivo sensor system for direct measurement of pressure in the human urinary bladder is
developed. The core component in the system is a small-sized and highly sensitive …
developed. The core component in the system is a small-sized and highly sensitive …
A polypyrrole-based strain sensor dedicated to measure bladder volume in patients with urinary dysfunction
This paper describes a new technique to measure urine volume in patients with urinary
bladder dysfunction. Polypyrrole–an electronically conducting polymer-is chemically …
bladder dysfunction. Polypyrrole–an electronically conducting polymer-is chemically …
Design and evaluation of potentiometric principles for bladder volume monitoring: a preliminary study
Recent advances in microelectronics and wireless transmission technology have led to the
development of various implantable sensors for real-time monitoring of bladder conditions …
development of various implantable sensors for real-time monitoring of bladder conditions …
A modular embedded system design for implantable wireless bladder pressure sensing
Here we present an embedded system for wireless measurement of urinary bladder
pressure. It can be implanted inside the bladder and transmitted data can be recorded using …
pressure. It can be implanted inside the bladder and transmitted data can be recorded using …
Urinary bladder volume reconstruction based on bioimpedance measurements: ex vivo and in vivo validation through implanted patch and needle electrodes
Restoring bladder sensation in patients with bladder dysfunctions by performing urinary
volume monitoring is an ambitious goal. The bioimpedance technique has shown promising …
volume monitoring is an ambitious goal. The bioimpedance technique has shown promising …