Estimation of the local statistical noise in emission computed tomography
NM Alpert, DA Chesler, JA Correia… - IEEE transactions on …, 1982 - ieeexplore.ieee.org
A simple modification of the filtered backprojection algorithm is presented for the
computation of the local statistical noise in emission computed tomography. The technique …
computation of the local statistical noise in emission computed tomography. The technique …
Resampling estimates of precision in emission tomography
DR Haynor, SD Woods - IEEE transactions on medical imaging, 1989 - ieeexplore.ieee.org
Methods for estimating the regional variance in emission tomography images which arise
from the Poisson nature of the raw data are discussed. The methods are based on the …
from the Poisson nature of the raw data are discussed. The methods are based on the …
Properties of statistical noise in positron emission tomography
E Tanaka, H Murayama - Physics and Engineering in Medical …, 1982 - spiedigitallibrary.org
The magnitude and texture of statistical noise in images of positron emission computed
tomography are evaluated analytically. A simple approximation method is presented for …
tomography are evaluated analytically. A simple approximation method is presented for …
Analysis of SPECT including scatter and attenuation using sophisticated Monte Carlo modeling methods
JW Beck, RJ Jaszczak, RE Coleman… - … on Nuclear Science, 1982 - ieeexplore.ieee.org
The effects of scatter and attenuation on single photon emission computed tomography
(SPECT) images can be analyzed with the aid of sophisticated Monte Carlo simulation …
(SPECT) images can be analyzed with the aid of sophisticated Monte Carlo simulation …
Noise properties of filtered-backprojection and ML-EM reconstructed emission tomographic images
DW Wilson, BMW Tsui - IEEE transactions on nuclear science, 1993 - ieeexplore.ieee.org
Noise properties of emission tomographic reconstructed images are compared using
maximum-likelihood-expectation-maximization (ML-EM) and filtered-backprojection (FBP) …
maximum-likelihood-expectation-maximization (ML-EM) and filtered-backprojection (FBP) …
Quantitative multi-detector emission computerized tomography using iterative attenuation compensation.
SC Moore, JA Brunelle, CM Kirsch - Journal of Nuclear Medicine …, 1982 - europepmc.org
An iterative procedure to correct for attenuation has been developed for a multidetector,
single-photon emission tomographic scanner. The difference between measured and …
single-photon emission tomographic scanner. The difference between measured and …
An approximation formula for the variance of PET region-of-interest values
RE Carson, Y Yan… - IEEE transactions on …, 1993 - ieeexplore.ieee.org
An approximation formula for the variance of positron emission tomography (PET) region-of-
interest (ROI) values has been developed, implemented, and evaluated. This formula does …
interest (ROI) values has been developed, implemented, and evaluated. This formula does …
Quantitation in positron emission computed tomography: 2. Effects of inaccurate attenuation correction
SC Huang, EJ Hoffman, ME Phelps… - Journal of computer …, 1979 - journals.lww.com
Abstract Effects of inaccurate attenuation correction on quantitation in positron emission
computed tomography were investigated by both computer simulation and theoretical …
computed tomography were investigated by both computer simulation and theoretical …
Data-dependent bandwidth selection for emission computed tomography reconstruction
Y Pawitan, F O'Sullivan - IEEE transactions on medical imaging, 1993 - ieeexplore.ieee.org
At present, the choice of bandwidth in emission computed tomography (ECT) reconstruction
is done by subjective means. The authors develop an automated objective selection …
is done by subjective means. The authors develop an automated objective selection …
Image improvements in positron-emission tomography due to measuring differential time-of-flight and using maximum-likelihood estimation
DG Politte - IEEE Transactions on Nuclear Science, 1990 - ieeexplore.ieee.org
Two distinctly different methods have been used to improve images produced in positron-
emission tomography. The first method is to measure the differential time-of-flight of the …
emission tomography. The first method is to measure the differential time-of-flight of the …
相关搜索
- emission computed tomography
- filtered backprojection noise properties
- positron emission image improvements
- positron emission differential time
- positron emission attenuation correction
- tomography reconstruction bandwidth selection
- approximation formula pet region
- positron emission tomography
- emission tomographic images