Design and analysis of robust active damping for LCL filters using digital notch filters

W Yao, Y Yang, X Zhang, F Blaabjerg… - IEEE Transactions on …, 2016 - ieeexplore.ieee.org
Resonant poles of LCL filters may challenge the entire system stability especially in digital-
controlled pulse width modulation (PWM) inverters. In order to tackle the resonance issues …

Analysis and comparison of notch filter and capacitor voltage feedforward active damping techniques for LCL grid-connected converters

E Rodriguez-Diaz, FD Freijedo… - … on Power Electronics, 2018 - ieeexplore.ieee.org
The use of LCL filters is a well-accepted solution to attenuate the harmonics created by the
pulsewidth modulation. However, inherently LCL filters have a resonance region where the …

Phase Reshaping via All-Pass Filters for Robust LCL-Filter Active Damping

W Yao, Y Yang, Y Xu, F Blaabjerg… - IEEE Transactions on …, 2019 - ieeexplore.ieee.org
Active damping is a common way to stabilize the current control of LCL-filtered converters. In
this paper, the stable region of-180° phase crossing is first identified within a predefined …

LCL-Filter Design for Robust Active Damping in Grid-Connected Converters

R Pena-Alzola, M Liserre, F Blaabjerg… - IEEE Transactions …, 2014 - ieeexplore.ieee.org
Grid-connected converters employ LCL-filters, instead of simple inductors, because they
allow lower inductances while reducing cost and size. Active damping, without dissipative …

Passivity Enhancement for LCL-Filtered Inverter With Grid Current Control and Capacitor Current Active Damping

X Wang, Y He, D Pan, H Zhang, Y Ma… - IEEE Transactions on …, 2021 - ieeexplore.ieee.org
This article takes a deep insight into the passivity-based design of LCL-filtered inverter with
grid current control and capacitor current active damping. It reveals that although an optimal …

Active damping-based control for grid-connected $ LCL $-filtered inverter with injected grid current feedback only

J Xu, S Xie, T Tang - IEEE Transactions on Industrial …, 2013 - ieeexplore.ieee.org
An LCL-type filter is widely used in the grid-connected inverter. However, with only injected
grid current control, the current harmonics and low bandwidth caused by the resonance …

Robust active damping methods for LCL filter-based grid-connected converters

MB Saïd-Romdhane, MW Naouar… - IEEE transactions on …, 2016 - ieeexplore.ieee.org
Grid-connected converters (GcCs) employ LCL filters instead of simple L filters in order to
meet new grid codes and their on-going changes in the near future. Active damping …

Exploring inherent damping characteristic of LCL-filters for three-phase grid-connected voltage source inverters

Y Tang, PC Loh, P Wang, FH Choo… - IEEE Transactions on …, 2011 - ieeexplore.ieee.org
This paper investigates the inherent damping characteristic of LCL-filters for three-phase
grid-connected voltage source inverters. Specifically, it is found that when the converter-side …

A robust passive damping method for LLCL-filter-based grid-tied inverters to minimize the effect of grid harmonic voltages

W Wu, Y Sun, M Huang, X Wang… - … on Power Electronics, 2013 - ieeexplore.ieee.org
In order to minimize the effect of the grid harmonic voltages, harmonic compensation is
usually adopted for a grid-tied inverter. However, a large variation of the grid inductance …

Design Considerations of Digitally Controlled LCL-Filtered Inverter With Capacitor- Current-Feedback Active Damping

X Wang, C Bao, X Ruan, W Li… - IEEE Journal of Emerging …, 2014 - ieeexplore.ieee.org
Due to the effect of the computation and modulation delays on the capacitor-current-
feedback active damping, the digitally controlled LCL-filtered inverter tends to be unstable …