Breast cancer detection: Comparison of digital mammography and digital breast tomosynthesis across non-dense and dense breasts
Introduction Breast density is associated with an increase in breast cancer risk and limits
early detection of the disease. This study assesses the diagnostic performance of …
early detection of the disease. This study assesses the diagnostic performance of …
Impact of breast density on diagnostic accuracy in digital breast tomosynthesis versus digital mammography: results from a European screening trial
J Olinder, K Johnson, A Åkesson, D Förnvik… - Breast Cancer …, 2023 - Springer
Background The diagnostic accuracy of digital breast tomosynthesis (DBT) and digital
mammography (DM) in breast cancer screening may vary per breast density subgroup. The …
mammography (DM) in breast cancer screening may vary per breast density subgroup. The …
Comparing mammographic density assessed by digital breast tomosynthesis or digital mammography: the breast cancer surveillance consortium
Background Consistency in reporting Breast Imaging Reporting and Data System (BI-RADS)
breast density on mammograms is important because breast density is used for breast …
breast density on mammograms is important because breast density is used for breast …
Digital mammography versus breast tomosynthesis: impact of breast density on diagnostic performance in population-based screening
BH Østerås, ACT Martinsen, R Gullien, P Skaane - Radiology, 2019 - pubs.rsna.org
Background Previous studies comparing digital breast tomosynthesis (DBT) to digital
mammography (DM) have shown conflicting results regarding breast density and diagnostic …
mammography (DM) have shown conflicting results regarding breast density and diagnostic …
Can digital breast tomosynthesis perform better than standard digital mammography work-up in breast cancer assessment clinic?
S Mall, J Noakes, M Kossoff, W Lee, M McKessar… - European …, 2018 - Springer
Purpose To compare the efficacy of use of digital breast tomosynthesis (DBT) with standard
digital mammography (DM) workup views in the breast cancer assessment clinic. Materials …
digital mammography (DM) workup views in the breast cancer assessment clinic. Materials …
Impact on the recall rate of digital breast tomosynthesis as an adjunct to digital mammography in the screening setting. A double reading experience and review of the …
LA Carbonaro, G Di Leo, P Clauser, RM Trimboli… - European journal of …, 2016 - Elsevier
Objectives To estimate the impact on recall rate (RR) of digital breast tomosynthesis (DBT)
associated with digital mammography (DM+ DBT), compared to DM alone, evaluate the …
associated with digital mammography (DM+ DBT), compared to DM alone, evaluate the …
A randomized controlled trial of digital breast tomosynthesis versus digital mammography in population-based screening in Bergen: interim analysis of performance …
HS Aase, ÅS Holen, K Pedersen, N Houssami… - European …, 2019 - Springer
Objectives To describe a randomized controlled trial (RCT) of digital breast tomosynthesis
including synthesized two-dimensional mammograms (DBT) versus digital mammography …
including synthesized two-dimensional mammograms (DBT) versus digital mammography …
Does reader performance with digital breast tomosynthesis vary according to experience with two-dimensional mammography?
L Tucker, FJ Gilbert, SM Astley, A Dibden, A Seth… - Radiology, 2017 - pubs.rsna.org
Purpose To assess whether individual reader performance with digital breast tomosynthesis
(DBT) and two-dimensional (2D) mammography varies with number of years of experience …
(DBT) and two-dimensional (2D) mammography varies with number of years of experience …
Comparing screening outcomes for digital breast tomosynthesis and digital mammography by automated breast density in a randomized controlled trial: results from …
N Moshina, HS Aase, AS Danielsen, IS Haldorsen… - Radiology, 2020 - pubs.rsna.org
Background Digital breast tomosynthesis (DBT) is considered superior to digital
mammography (DM) for women with dense breasts. Purpose To identify differences in …
mammography (DM) for women with dense breasts. Purpose To identify differences in …
The effect of the addition of tomosynthesis to digital mammography on reader recall rate and reader confidence in the UK prevalent screening round
N Upadhyay, N Soneji, V Stewart, G Ralleigh - Clinical Radiology, 2018 - Elsevier
Aim To compare reader recall rate and confidence associated with recall decisions for digital
mammography (DM) alone with DM plus digital breast tomosynthesis (DBT) in the prevalent …
mammography (DM) alone with DM plus digital breast tomosynthesis (DBT) in the prevalent …
相关搜索
- digital breast tomosynthesis
- breast cancer detection
- diagnostic performance breast tomosynthesis
- breast density digital mammography
- women with dense breasts
- dense breasts meta analysis
- performance indicators breast tomosynthesis
- diagnostic accuracy breast tomosynthesis
- reading experience breast tomosynthesis
- diagnosis in women breast tomosynthesis
- recall rate breast tomosynthesis
- screening setting breast tomosynthesis
- screening outcomes breast tomosynthesis
- interim analysis breast tomosynthesis
- breast cancer screening
- breast cancer assessment clinic