Free-breathing, zero-TE MR lung imaging

F Gibiino, L Sacolick, A Menini, L Landini… - … Resonance Materials in …, 2015 - Springer
Object The investigation of three-dimensional radial, zero-echo time (TE) imaging for high-
resolution, free-breathing magnetic resonance (MR) lung imaging using prospective and …

DC‐gated high resolution three‐dimensional lung imaging during free‐breathing

S Weick, FA Breuer, P Ehses, M Völker… - Journal of Magnetic …, 2013 - Wiley Online Library
Purpose: To use the acquisition of the k‐space center signal (DC signal) implemented into a
Cartesian three‐dimensional (3D) FLASH sequence for retrospective respiratory self‐gating …

Dynamic pulmonary MRI using motion‐state weighted motion‐compensation (MostMoCo) reconstruction with ultrashort TE: a structural and functional study

Z Ding, Z Cheng, H She, B Liu, Y Yin… - Magnetic Resonance in …, 2022 - Wiley Online Library
Purpose To improve the quality of structural images and the quantification of ventilation in
free‐breathing dynamic pulmonary MRI. Methods A 3D radial ultrashort TE (UTE) sequence …

Oxygen‐enhanced functional lung imaging using a contemporary 0.55 T MRI system

I Bhattacharya, R Ramasawmy, A Javed… - NMR in …, 2021 - Wiley Online Library
The purpose of this study was to evaluate oxygen‐enhanced pulmonary imaging at 0.55 T
with 3D stack‐of‐spirals ultrashort‐TE (UTE) acquisition. Oxygen‐enhanced pulmonary MRI …

Lung imaging under free‐breathing conditions

M Oechsner, ED Pracht, D Staeb… - … in Medicine: An …, 2009 - Wiley Online Library
Respiratory motion and pulsatile blood flow can generate artifacts in morphological and
functional lung imaging. Total acquisition time, and thus the achievable signal to noise ratio …

Submillimeter lung MRI at 0.55 T using balanced steady‐state free precession with half‐radial dual‐echo readout (bSTAR)

G Bauman, NG Lee, Y Tian, O Bieri… - Magnetic Resonance …, 2023 - Wiley Online Library
Purpose To demonstrate the feasibility of high‐resolution morphologic lung MRI at 0.55 T
using a free‐breathing balanced steady‐state free precession half‐radial dual‐echo …

Respiratory motion–resolved four-dimensional zero echo time (4D ZTE) lung MRI using retrospective soft gating: feasibility and image quality compared with 3D ZTE

K Bae, KN Jeon, MJ Hwang, JS Lee, SE Park… - European …, 2020 - Springer
Objectives To evaluate the feasibility and image quality of respiratory motion–resolved 4D
zero echo time (ZTE) lung MRI compared with that of 3D ZTE. Methods Our institutional …

A double echo ultra short echo time (UTE) acquisition for respiratory motion‐suppressed high resolution imaging of the lung

J Delacoste, J Chaptinel… - Magnetic resonance …, 2018 - Wiley Online Library
Purpose Magnetic resonance imaging is a promising alternative to computed tomography
for lung imaging. However, organ motion and poor signal‐to‐noise ratio, arising from short …

Oxygen‐enhanced 3D radial ultrashort echo time magnetic resonance imaging in the healthy human lung

SJ Kruger, SB Fain, KM Johnson… - NMR in …, 2014 - Wiley Online Library
The purpose of this work was to use 3D radial ultrashort echo time (UTE) MRI to perform
whole‐lung oxygen‐enhanced (OE) imaging in humans. Eight healthy human subjects …

Simultaneous evaluation of lung anatomy and ventilation using 4D respiratory‐motion‐resolved ultrashort echo time sparse MRI

LI Feng, J Delacoste, D Smith… - Journal of Magnetic …, 2019 - Wiley Online Library
Background Computed tomography (CT) and spirometry are the current standard methods
for assessing lung anatomy and pulmonary ventilation, respectively. However, CT provides …