Impact of diastolic function parameters on the risk for left atrial appendage thrombus in patients with nonvalvular atrial fibrillation: a prospective study
R Doukky, E Garcia-Sayan, M Patel, R Pant… - Journal of the American …, 2016 - Elsevier
Background In patients with nonvalvular atrial fibrillation (NVAF), the impact of left ventricular
diastolic function on the risk for left atrial appendage (LAA) thrombus has not been …
diastolic function on the risk for left atrial appendage (LAA) thrombus has not been …
The value of diastolic function parameters in the prediction of left atrial appendage thrombus in patients with nonvalvular atrial fibrillation
Background Left ventricular diastolic impairment and consequently elevated filling pressure
may contribute to stasis leading to left atrial appendage thrombus (LAAT) in nonvalvular …
may contribute to stasis leading to left atrial appendage thrombus (LAAT) in nonvalvular …
A new risk model of assessing left atrial appendage thrombus in patients with atrial fibrillation–Using multiple clinical and transesophageal echocardiography …
L Chen, A Zinda, N Rossi, XJ Han, S Sprankle… - International Journal of …, 2020 - Elsevier
Backgrounds Predicting left atrial appendage thrombus (LAAT) in non-valvular atrial
fibrillation (NVAF) patients need more precisely quantified risk models. In this study, we …
fibrillation (NVAF) patients need more precisely quantified risk models. In this study, we …
External validation of a novel transthoracic echocardiographic tool in predicting left atrial appendage thrombus formation in patients with nonvalvular atrial fibrillation
R Doukky, A Khandelwal… - European Heart …, 2013 - academic.oup.com
Background A recent study demonstrated that in patients with nonvalvular atrial fibrillation
(AF), a ratio of left ventricular ejection fraction (LVEF) to the left atrial volume index (LAVI) of< …
(AF), a ratio of left ventricular ejection fraction (LVEF) to the left atrial volume index (LAVI) of< …
Effect of elevated left ventricular diastolic filling pressure on the frequency of left atrial appendage thrombus in patients with nonvalvular atrial fibrillation
K Iwakura, A Okamura, Y Koyama, M Date… - The American journal of …, 2011 - Elsevier
We investigated the relation between left ventricular diastolic dysfunction and left atrial
appendage (LAA) thrombus in patients with atrial fibrillation (AF). We performed …
appendage (LAA) thrombus in patients with atrial fibrillation (AF). We performed …
Echocardiographic predictors of left atrial appendage thrombus formation
S Ayirala, S Kumar, DM O'Sullivan… - Journal of the American …, 2011 - Elsevier
BACKGROUND: Although transesophageal echocardiography is the definitive test for the
detection of left atrial (LA) appendage thrombus, transthoracic echocardiography has yet to …
detection of left atrial (LA) appendage thrombus, transthoracic echocardiography has yet to …
Prediction of left atrial appendage thrombi in non-valvular atrial fibrillation
S Habara, K Dote, M Kato, S Sasaki, K Goto… - European heart …, 2007 - academic.oup.com
Aims There is little knowledge about the predictors of left atrial appendage (LAA) thrombi in
non-valvular atrial fibrillation (NVAF). We investigated the ability of d-dimer to predict LAA …
non-valvular atrial fibrillation (NVAF). We investigated the ability of d-dimer to predict LAA …
Biomarkers for predicting left atrial or left atrial appendage thrombus in anticoagulated patients with nonvalvular atrial fibrillation
X Zhou, Z Wang, S Dou, K Chen, E Liu… - Cardiology …, 2020 - Wiley Online Library
Purpose. Although atrial fibrillation (AF) is often associated with thromboembolic
complications, there is no definite biomarker for detecting the presence of thrombi in the left …
complications, there is no definite biomarker for detecting the presence of thrombi in the left …
Low wall velocity of left atrial appendage measured by trans-thoracic echocardiography predicts thrombus formation caused by atrial appendage dysfunction
H Tamura, T Watanabe, O Hirono, S Nishiyama… - Journal of the American …, 2010 - Elsevier
BACKGROUND: Atrial fibrillation is associated with ischemic stroke because of thrombi that
form within the left atrial appendage (LAA). The aim of this study was to develop a new …
form within the left atrial appendage (LAA). The aim of this study was to develop a new …
Prevalence and clinical determinants of left atrial appendage thrombus in patients with atrial fibrillation before pulmonary vein isolation
M Nishikii-Tachibana, N Murakoshi, Y Seo… - The American journal of …, 2015 - Elsevier
The CHADS 2 score is considered a reliable predictor of stroke/thromboembolism risk in
patients with atrial fibrillation (AF). However, thromboembolism can occasionally occur even …
patients with atrial fibrillation (AF). However, thromboembolism can occasionally occur even …
相关搜索
- appendage thrombus function parameters
- appendage thrombus atrial fibrillation
- atrial fibrillation echocardiography parameters
- appendage thrombus clinical determinants
- atrial fibrillation clinical determinants
- appendage thrombus filling pressure
- appendage dysfunction thrombus formation
- appendage thrombus vein isolation
- atrial fibrillation vein isolation
- appendage thrombus echocardiography parameters