Intermethod variability of sodium and potassium results: patients sera and commercially available control sera

G Cattozzo, A Fabi, C Franzini - 1997 - degruyter.com
Sodium and potassium were measured in sets of 102 to 107 patients sera, and in 31
commercially available control sera. The results from four routine analytical …

[引用][C] Standardization of sodium/potassium revisited

MF Burritt - Clinical chemistry, 1992 - academic.oup.com
With the pending new CLIA regulations, the issue of standardization has become more
important. AACC's efforts in the areas of standardization and development of standard …

Evaluation for four reagent kits and two flame photometers used to determine sodium and potassium in serum

EK Kim, LD Waddell, JE Logan - Clinical Chemistry, 1972 - academic.oup.com
Abstract The Stanbio and Medi-Chem sodium and potassium kits were evaluated and the
results compared with those obtained with the Coleman Jr. Model 21, NIL 4-7000, and …

International consensus on the standardization of sodium and potassium measurements by ion-selective electrodes in undiluted samples

WR Küpmann, T Höbbel - Scandinavian journal of clinical and …, 1996 - Taylor & Francis
The International Federation of Clinical Chemistry (FCC) and the National Committee for
Clinical Laboratory Standards (NCCLS) are about to recommend to adjust sodium and …

[PDF][PDF] Evaluation of an instrument (Nova-1) for direct potentiometric analysis of sodium and potassium in blood and their indirect potentiometric determination in urine.

JH Ladenson - Clinical chemistry, 1979 - Citeseer
Materials and Methods Direct potentiometric analysis of sodium and potassium was done
with an Orion SS/30 sodium/potassium analyzer (Orion Biomedical, Inc., 11 Blackstone St …

Survey of serum potassium reference measurements

JE Van Nuwenborg, LM Thienpont… - Annals of clinical …, 1999 - journals.sagepub.com
We compared the quality of reference measurements for serum potassium in four reference
laboratories from three different European countries, using a panel of 60 native patients' …

Evaluation of an Automated Selective-Ion Electrolyte Analyzer for Measuring Na+, K+, and Cl- in Serum

JA Lustgarten, RE Wenk, C Byrd, B Hall - Clinical Chemistry, 1974 - academic.oup.com
An automated analyzer, in which ion-selective electrodes are used to measure sodium,
potassium, and chloride in serum, was assessed in a clinical setting. Day-to-day precision …

[PDF][PDF] Normal range for serum sodium by ion-selective electrode analysis exceeds that by flame photometry.

W Annan, NA Kirwan, WS Robertson - Clinical chemistry, 1979 - Citeseer
American Hospital Supply (UK) Ltd., Didcot, Oxon. An instrument supplied for a trial period in
our laboratory produced results for plasma and serum so-dium that differed significantly from …

A multilaboratory-evaluated reference method for the determination of serum sodium.

R Schaffer, RA Velapoldi, RC Paule, J Mandel… - Clinical …, 1981 - academic.oup.com
We carried out a statistically designed, multilaboratory study to evaluate a flame atomic
emission spectroscopic (FAES) method for serum sodium as a Reference Method. definitive …

Ektachem slides for direct potentiometric determination of sodium in plasma: Effect of natremia, blood ph, and type of electrolyte reference fluid on concordance with …

A Boeyckens, J Schots, H Vandenplas… - Clinical …, 1992 - academic.oup.com
With electrolyte reference fluid (ERF) 00, results from Kodak Ektachem slides for the direct
potentiometric assay of sodium in plasma were significantly correlated with results from …