Single breath-hold, whole lung morphometry with hyperpolarized 3he using parallel imaging
YV Chang, JD Quirk, M Castro… - International Society for …, 2015 - archive.ismrm.org
Although diffusion-based in vivo lung morphometry with hyperpolarized gases MRI is a
powerful tool to study lung diseases, it is usually performed in a 2D mode with only a few …
powerful tool to study lung diseases, it is usually performed in a 2D mode with only a few …
In vivo lung morphometry with accelerated hyperpolarized 3He diffusion MRI: A preliminary study
YV Chang, JD Quirk… - Magnetic resonance in …, 2015 - Wiley Online Library
Purpose Parallel imaging can be used to reduce imaging time and to increase the spatial
coverage in hyperpolarized gas magnetic resonance imaging of the lung. In this proof‐of …
coverage in hyperpolarized gas magnetic resonance imaging of the lung. In this proof‐of …
Probing lung microstructure with hyperpolarized 3He gradient echo MRI
AL Sukstanskii, JD Quirk, DA Yablonskiy - NMR in Biomedicine, 2014 - Wiley Online Library
In this paper we demonstrate that gradient echo MRI with hyperpolarized 3He gas can be
used for simultaneously extracting in vivo information about lung ventilation properties …
used for simultaneously extracting in vivo information about lung ventilation properties …
Imaging lung microstructure in mice with hyperpolarized 3He diffusion MRI
W Wang, NM Nguyen, DA Yablonskiy… - Magnetic resonance …, 2011 - Wiley Online Library
Quantitative measurement of lung microstructure is of great significance in assessment of
pulmonary disease, particularly in the earliest stages. The technique for MRI‐based 3He …
pulmonary disease, particularly in the earliest stages. The technique for MRI‐based 3He …
Diffusion lung imaging with hyperpolarized gas MRI
DA Yablonskiy, AL Sukstanskii, JD Quirk - NMR in Biomedicine, 2017 - Wiley Online Library
Lung imaging using conventional 1H MRI presents great challenges because of the low
density of lung tissue, lung motion and very fast lung tissue transverse relaxation (typical T2 …
density of lung tissue, lung motion and very fast lung tissue transverse relaxation (typical T2 …
Rapid Single Shot Whole Lung Acquisition of for Hyperpolarized Gas MRI Biomarkers of Airspace Enlargement.
Hyperpolarized gas pulmonary MRI provides physiologically relevant biomarkers of
obstructive lung disease including emphysema, bronchopulmonary dysplasia, congenital …
obstructive lung disease including emphysema, bronchopulmonary dysplasia, congenital …
High Resolution 3He Pulmonary MRI
MS Fox, AV Ouriadov - Magnetic Resonance Imaging, 2019 - books.google.com
Hyperpolarized gas MRI of the mouse lung is of great interest due to the urgent need for
novel biomarkers for the assessment of respiratory-disease progression and development of …
novel biomarkers for the assessment of respiratory-disease progression and development of …
Whole lung morphometry with 3D multiple b‐value hyperpolarized gas MRI and compressed sensing
Purpose To demonstrate three‐dimensional (3D) multiple b‐value diffusion‐weighted (DW)
MRI of hyperpolarized 3He gas for whole lung morphometry with compressed sensing (CS) …
MRI of hyperpolarized 3He gas for whole lung morphometry with compressed sensing (CS) …
3D hyperpolarized 3He MR imaging of the lung using an interleaved-cylindrical k-space trajectory
K Ruppert, JP Mugler III - Proceedings of the 9th Annual Meeting of …, 2001 - cds.ismrm.org
Lung ventilation imaging using hyperpolarized 3He is performed predominantly with two-
dimensional (2D) gradient-echo (GRE) pulse sequences [1]. However, for a full evaluation of …
dimensional (2D) gradient-echo (GRE) pulse sequences [1]. However, for a full evaluation of …
Single‐scan acquisition of registered hyperpolarized 3He ventilation and ADC images using a hybrid 2D gradient‐echo sequence
JM Wild, N Woodhouse, K Teh - Magnetic Resonance in …, 2007 - Wiley Online Library
The pulse sequences for hyperpolarized 3He lung MRI that have made the most clinical
impact to date are 1) those that supply regional apparent diffusion coefficient (ADC) …
impact to date are 1) those that supply regional apparent diffusion coefficient (ADC) …