Clinical application of transcranial colour-coded duplex sonography–a review.

SG Zipper, E Stolz - European Journal of Neurology, 2002 - search.ebscohost.com
Transcranial colour-coded duplex sonography (TCCS) is a new and non-invasive
ultrasound application that combines both imaging of intracranial vessels and parenchymal …

Echo-enhanced transcranial color-coded duplex sonography in the diagnosis of cerebrovascular events: a validation study

A Kunz, G Hahn, D Mucha, A Müller… - American journal …, 2006 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Transcranial color-coded duplex sonography (TCCD) is a
diagnostic technique for evaluation of intracranial arteries in patients with acute stroke. Echo …

Diagnosis of internal carotid artery stenosis greater than 70% with power Doppler duplex sonography

M Koga, K Kimura, K Minematsu… - American journal of …, 2001 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Duplex sonography is an effective tool for evaluating
internal carotid artery (ICA) stenosis, and power Doppler imaging has improved its value in …

Optimal values of flow velocity on transcranial Doppler in grading middle cerebral artery stenosis in comparison with magnetic resonance angiography

S Gao, WWM Lam, YL Chan, J Yan Liu… - Journal of …, 2002 - Wiley Online Library
Background and purpose. To investigate the optimal values of flow velocity on transcranial
Doppler (TCD) in grading the severity of middle cerebral artery (MCA) stenosis in …

Preoperative evaluation of carotid artery stenosis: comparison of contrast-enhanced MR angiography and duplex sonography with digital subtraction angiography

I Borisch, M Horn, B Butz, N Zorger… - American journal …, 2003 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Contrast-enhanced MR angiography and extracranial
color-coded duplex sonography are noninvasive, preoperative imaging modalities for …

Middle cerebral artery vasospasm: transcranial color-coded duplex sonography versus conventional nonimaging transcranial Doppler sonography

M Swiat, J Weigele, RW Hurst, SE Kasner… - Critical care …, 2009 - journals.lww.com
Objective: To prospectively compare accuracies of transcranial color-coded duplex
sonography (TCCS) and transcranial Doppler sonography (TCD) in the diagnosis of middle …

Diagnostic value of three‐dimensional transcranial contrast duplex sonography

A Delcker, B Turowski - Journal of Neuroimaging, 1997 - Wiley Online Library
This study evaluated intracranial cerebral arteries using a new data acquisition system for
transcranial three‒dimensional (3D) ultrasonography with and without an echo contrast …

[引用][C] Ultrasound diagnosis of cerebrovascular disease: Doppler sonography of the extra-and intracranial arteries duplex scanning

GM Von Reutern, HJ von Büdingen - 1993 - Thieme Medical Publishers

Contrast-enhanced transcranial color-coded duplexsonography in stroke patients with limited bone windows

G Gahn, J Gerber, S Hallmeyer… - American journal …, 2000 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Thickening of the temporal bone in stroke-age patients
may obviate sonographic evaluation of the circle of Willis in 20% to 30% of patients. We …

Duplex sonography of the cerebral arteries: efficacy, limitations, and indications.

WJ ZWiebel - AJR. American journal of roentgenology, 1992 - Am Roentgen Ray Soc
This review considers the capabilities and limitations of duplex sonography in the diagnosis
of abnormalities of the cerebral vasculature. Duplex sonography is an elegant union of B …