In-vitro/in-vivo comparison of inhaled salbutamol dose delivered by jet nebulizer, vibrating mesh nebulizer and metered dose inhaler with spacer during non-invasive …

A Hassan, R Salah Eldin… - Experimental lung …, 2017 - Taylor & Francis
Background: Patients receiving noninvasive ventilation (NIV) may benefit from medical
aerosol, but most guidance on dosing with different aerosol devices is limited to in-vitro …

Inhaled salbutamol dose delivered by jet nebulizer, vibrating mesh nebulizer and metered dose inhaler with spacer during invasive mechanical ventilation

MHE ElHansy, ME Boules, AFM El Essawy… - Pulmonary …, 2017 - Elsevier
Background Patient receiving invasive mechanical ventilation (IMV) may benefit from
medical aerosol, but guidance on dosing with different aerosol devices is limited to in-vitro …

Effects of fill volume and humidification on aerosol delivery during single-limb noninvasive ventilation

H Saeed, M Mohsen, AS Eldin, AA Elberry… - Respiratory …, 2018 - rc.rcjournal.com
BACKGROUND: The aim of this work was to determine the effect of fill volume and
humidification change on aerosol delivery during single-limb noninvasive ventilation (NIV) …

[HTML][HTML] Effect of nebulizer designs on aerosol delivery during non-invasive mechanical ventilation: a modeling study of in vitro data

H Saeed, AA Elberry, AS Eldin, H Rabea… - Pulmonary …, 2017 - Springer
Introduction Nebulizers used to deliver aerosol during non-invasive mechanical ventilation
(NIV) have many types, each type has many different designs. This study aimed to determine …

[HTML][HTML] In-vitro characterization of the aerosolized dose during non-invasive automatic continuous positive airway pressure ventilation

A Hassan, H Rabea, RRS Hussein, R Salah Eldin… - Pulmonary …, 2016 - Springer
Introduction Many devices (eg, nebulizers and spacers) are used to deliver aerosol in a non-
invasive ventilation circuit (NIV) without any special recommendation. The aim of the present …

Performance of large spacer versus nebulizer T-piece in single-limb noninvasive ventilation

HS Harb, AA Elberry, H Rabea, M Fathy… - Respiratory …, 2018 - rc.rcjournal.com
BACKGROUND: Predosing patients with COPD with salbutamol by using a pressurized
metered-dose-inhaler (pMDI) as a bronchodilator was hypothesized to improve the …

[HTML][HTML] Effects of ventilator settings, nebulizer and exhalation port position on albuterol delivery during non-invasive ventilation: an in-vitro study

Y Sutherasan, L Ball, P Raimondo, V Caratto… - BMC Pulmonary …, 2017 - Springer
Background Few studies have investigated the factors affecting aerosol delivery during non-
invasive ventilation (NIV). Our aim was to investigate, using a bench-top model, the effect of …

In Vitro Comparison of Five Nebulizers During Noninvasive Ventilation: Analysis of Inhaled and Lost Doses

JB Michotte, E Jossen, J Roeseler, G Liistro… - Journal of aerosol …, 2014 - liebertpub.com
Background: Few studies on performance comparison of nebulizer systems coupled with a
single-limb circuit bilevel ventilator are available. Most of these data compared the aerosol …

Which nebulizer position should be avoided? An extended study of aerosol delivery and ventilator performance during noninvasive positive pressure ventilation

Y Peng, B Dai, CX Hu, J Su, W Tan, HW Zhao, J Kang - Respiration, 2018 - karger.com
Background: Research on the effect of nebulizer location on aerosol delivery during
noninvasive ventilation has reached inconsistent conclusions. Objective: To investigate the …

Effect of oxygen flow on aerosol delivery from a nebulizer with a holding chamber

RM Sarhan, AA Elberry, NS Abdelwahab… - Respiratory …, 2019 - rc.rcjournal.com
BACKGROUND: A new holding chamber was designed to be used with a vibrating mesh
nebulizer to increase the total inhalable dose for patients. It facilitates intermittent and …