Measurement of the reduced scattering coefficient of turbid media using single fiber reflectance spectroscopy: fiber diameter and phase function dependence
SC Kanick, UA Gamm, M Schouten… - Biomedical optics …, 2011 - opg.optica.org
This paper presents a relationship between the intensity collected by a single fiber
reflectance device (RSF) and the fiber diameter (dfib) and the reduced scattering coefficient …
reflectance device (RSF) and the fiber diameter (dfib) and the reduced scattering coefficient …
Measurement of tissue scattering properties using multi-diameter single fiber reflectance spectroscopy: in silico sensitivity analysis
UA Gamm, SC Kanick, H Sterenborg… - Biomedical optics …, 2011 - opg.optica.org
Multiple diameter single fiber reflectance (MDSFR) measurements of turbid media can be
used to determine the reduced scattering coefficient (μ′ s) and a parameter that …
used to determine the reduced scattering coefficient (μ′ s) and a parameter that …
Method to quantitatively estimate wavelength-dependent scattering properties from multidiameter single fiber reflectance spectra measured in a turbid medium
SC Kanick, UA Gamm, HJCM Sterenborg… - Optics letters, 2011 - opg.optica.org
This study utilizes experimentally validated Monte Carlo simulations to identify a
mathematical formulation of the reflectance intensity collected by a single fiber probe …
mathematical formulation of the reflectance intensity collected by a single fiber probe …
Quantification of the reduced scattering coefficient and phase-function-dependent parameter γ of turbid media using multidiameter single fiber reflectance …
Multidiameter single fiber reflectance (MDSFR) spectroscopy is a method that allows the
quantification of μs′ and the phase-function-dependent parameter γ of a turbid medium by …
quantification of μs′ and the phase-function-dependent parameter γ of a turbid medium by …
Measurement of tissue optical properties by the use of oblique-incidence optical fiber reflectometry
Fiber-optic-based oblique-incidence reflectometry is a simple and accurate method for
measuring the absorption and reduced scattering coefficients μ_a and μs′ of semi-infinite …
measuring the absorption and reduced scattering coefficients μ_a and μs′ of semi-infinite …
Method to quantitate absorption coefficients from single fiber reflectance spectra without knowledge of the scattering properties
This study presents a methodology to accurately extract the absorption coefficient from
single fiber reflectance spectra measured in turbid media without a priori knowledge of …
single fiber reflectance spectra measured in turbid media without a priori knowledge of …
Estimation of optical properties by spatially resolved reflectance spectroscopy in the subdiffusive regime
P Naglič, F Pernuš, B Likar… - Journal of biomedical …, 2016 - spiedigitallibrary.org
We propose and objectively evaluate an inverse Monte Carlo model for estimation of
absorption and reduced scattering coefficients and similarity parameter γ from spatially …
absorption and reduced scattering coefficients and similarity parameter γ from spatially …
Evaluation of a fiberoptic-based system for measurement of optical properties in highly attenuating turbid media
D Sharma, A Agrawal, LS Matchette… - Biomedical engineering …, 2006 - Springer
Background Accurate measurements of the optical properties of biological tissue in the
ultraviolet A and short visible wavelengths are needed to achieve a quantitative …
ultraviolet A and short visible wavelengths are needed to achieve a quantitative …
Subdiffuse scattering model for single fiber reflectance spectroscopy
AL Post, HJCM Sterenborg, FG Woltjer… - … of biomedical optics, 2020 - spiedigitallibrary.org
To detect small-scale changes in tissue with optical techniques, small sampling volumes are
required. Single fiber reflectance (SFR) spectroscopy has a sampling depth of a few …
required. Single fiber reflectance (SFR) spectroscopy has a sampling depth of a few …
Refractive index measurement using single fiber reflectance spectroscopy
A method using single fiber reflectance spectroscopy to measure the refractive indices of
transparent and turbid media over a broad wavelength range is presented and tested. For …
transparent and turbid media over a broad wavelength range is presented and tested. For …
相关搜索
- scattering coefficient phase function
- scattering coefficient turbid media
- turbid media phase function
- scattering coefficient fiber diameter
- fiber diameter phase function
- fiber diameter turbid media
- scattering properties absorption coefficients
- scattering coefficient experimental validation
- scattering properties fiber reflectance
- experimental validation phase function
- turbid media optical properties
- reflectance spectroscopy optical properties
- reflectance spectroscopy subdiffusive regime
- turbid media experimental validation
- turbid medium fiber reflectance
- scattering properties turbid medium