Clinical implementation of full Monte Carlo dose calculation in proton beam therapy

H Paganetti, H Jiang, K Parodi… - Physics in Medicine …, 2008 - iopscience.iop.org
The goal of this work was to facilitate the clinical use of Monte Carlo proton dose calculation
to support routine treatment planning and delivery. The Monte Carlo code Geant4 was used …

Characterizing a proton beam scanning system for Monte Carlo dose calculation in patients

C Grassberger, A Lomax… - Physics in Medicine & …, 2014 - iopscience.iop.org
The presented work has two goals. First, to demonstrate the feasibility of accurately
characterizing a proton radiation field at treatment head exit for Monte Carlo dose …

Monte Carlo simulations for configuring and testing an analytical proton dose-calculation algorithm

W Newhauser, J Fontenot, Y Zheng, J Polf… - Physics in Medicine …, 2007 - iopscience.iop.org
Contemporary treatment planning systems for proton radiotherapy typically use analytical
pencil-beam algorithms—which require a comprehensive set of configuration data—to …

Clinical validation of a GPU-based Monte Carlo dose engine of a commercial treatment planning system for pencil beam scanning proton therapy

F Fracchiolla, E Engwall, M Janson, F Tamm… - Physica Medica, 2021 - Elsevier
Purpose To perform the validation of the GPU-based (Graphical Processing Unit based)
proton Monte Carlo (MC) dose engine implemented in a commercial TPS (RayStation 10B) …

Characterization and validation of a Monte Carlo code for independent dose calculation in proton therapy treatments with pencil beam scanning

F Fracchiolla, S Lorentini, L Widesott… - Physics in Medicine & …, 2015 - iopscience.iop.org
We propose a method of creating and validating a Monte Carlo (MC) model of a proton
Pencil Beam Scanning (PBS) machine using only commissioning measurements and …

A Monte Carlo-based treatment planning tool for proton therapy

A Mairani, TT Böhlen, A Schiavi… - Physics in Medicine …, 2013 - iopscience.iop.org
In the field of radiotherapy, Monte Carlo (MC) particle transport calculations are recognized
for their superior accuracy in predicting dose and fluence distributions in patient geometries …

Quantification of proton dose calculation accuracy in the lung

C Grassberger, J Daartz, S Dowdell, T Ruggieri… - International Journal of …, 2014 - Elsevier
Purpose To quantify the accuracy of a clinical proton treatment planning system (TPS) as
well as Monte Carlo (MC)–based dose calculation through measurements and to assess the …

Validation and clinical implementation of an accurate Monte Carlo code for pencil beam scanning proton therapy

S Huang, M Kang, K Souris, C Ainsley… - Journal of applied …, 2018 - Wiley Online Library
Monte Carlo (MC)‐based dose calculations are generally superior to analytical dose
calculations (ADC) in modeling the dose distribution for proton pencil beam scanning (PBS) …

Monte Carlo dose calculations for spot scanned proton therapy

A Tourovsky, AJ Lomax, U Schneider… - Physics in Medicine & …, 2005 - iopscience.iop.org
Density heterogeneities can have a profound effect on dose distributions for proton therapy.
Although analytical calculations in homogeneous media are relatively straightforward, the …

Monte Carlo calculations for absolute dosimetry to determine machine outputs for proton therapy fields

H Paganetti - Physics in Medicine & Biology, 2006 - iopscience.iop.org
The prescribed dose in radiation therapy has to be converted into machine monitor units for
patient treatment. This is done routinely for each spread-out Bragg peak (SOBP) field either …