A polymer lab chip sensor with microfabricated planar silver electrode for continuous and on-site heavy metal measurement

W Jung, A Jang, PL Bishop, CH Ahn - Sensors and Actuators B: Chemical, 2011 - Elsevier
This paper presents a reusable polymer lab chip sensor for continuous and on-site heavy
metal monitoring in nature. In particular, detection of lead (Pb (II)), which is the most common …

An on-site heavy metal analyzer with polymer lab-on-a-chips for continuous sampling and monitoring

Z Zou, A Jang, ET MacKnight, PM Wu, J Do… - IEEE Sensors …, 2009 - ieeexplore.ieee.org
An on-site analyzer system for monitoring of heavy metals has been presented. This
analyzer can automatically perform long-term continuous water sampling and on-site heavy …

Microfluidic sensor integrated with nanochannel liquid conjunct Ag/AgCl reference electrode for trace Pb (II) measurement

J Dai, W Gao, J Yin, L Liang, J Zou, Q Jin - Analytica Chimica Acta, 2021 - Elsevier
Pollution due to heavy metals is becoming increasingly hazardous; therefore, demand for
the large-scale deployment of sensor nodes for water quality monitoring has increased. The …

Environmentally friendly disposable sensors with microfabricated on-chip planar bismuth electrode for in situ heavy metal ions measurement

Z Zou, A Jang, E MacKnight, PM Wu, J Do… - Sensors and Actuators B …, 2008 - Elsevier
This paper presents an environmentally friendly disposable heavy metal ion sensor for in
situ and online monitoring in the nature and physiological systems. The miniaturized sensor …

High sensitivity and specificity simultaneous determination of lead, cadmium and copper using μPAD with dual electrochemical and colorimetric detection

S Chaiyo, A Apiluk, W Siangproh… - Sensors and Actuators B …, 2016 - Elsevier
A bismuth-modified electrode can increase the sensitivity of lead and cadmium detection.
However, use of a bismuth-modified electrode in the detection of copper remains limited …

Electrochemical sensing of lead in drinking water using copper foil bonded with polymer

TZ Redhwan, Y Ali, MMR Howlader, YM Haddara - Sensors, 2023 - mdpi.com
Levels of lead (Pb) in tap water that are well below established guidelines are now
considered harmful, so the detection of sub-parts-per-billion (ppb) Pb levels is crucial. In this …

Miniaturized electrochemical sensor with micropillar array working electrode for trace lead online measurement in tap water

X Hu, H Guo, T Qi, W Fan, C Jia, B Xu… - Journal of …, 2019 - iopscience.iop.org
A compact, durable, low-reagent-usage, portable miniaturized electrochemical sensor is
successfully developed for the high sensitivity detection of trace lead. We fabricated …

Determination of lead with a copper-based electrochemical sensor

W Kang, X Pei, CA Rusinek, A Bange… - Analytical …, 2017 - ACS Publications
This work demonstrates determination of lead (Pb) in surface water samples using a low-
cost copper (Cu)-based electrochemical sensor. Heavy metals require careful monitoring …

Potentiometric and voltammetric polymer lab chip sensors for determination of nitrate, pH and Cd (II) in water

A Jang, Z Zou, KK Lee, CH Ahn, PL Bishop - Talanta, 2010 - Elsevier
Due to their toxicity to humans and animals, heavy metals and nitrate in groundwater are of
particular concern. The combination of high toxicity and widespread occurrence has created …

Development and characterisation of disposable gold electrodes, and their use for lead (II) analysis

MFM Noh, IE Tothill - Analytical and bioanalytical chemistry, 2006 - Springer
There is an increasing need to assess the harmful effects of heavy-metal-ion pollution on the
environment. The ability to detect and measure toxic contaminants on site using simple, cost …