A novel optical sensor for uranium determination

A Safavi, M Bagheri - Analytica chimica acta, 2005 - Elsevier
A metal ion indicator, Alizarin Red S, was tested for its potential use in uranium selective
optode membrane. The water-soluble indicator was lipophilized in the form of an ion pair …

Optode for uranium (VI) determination in aqueous medium

JM Joshi, PN Pathak, AK Pandey, VK Manchanda - Talanta, 2008 - Elsevier
A colorimetric method for simultaneous preconcentration and determination of uranium (VI)
anions from aqueous samples was developed using a membrane optode formed by …

Membrane optode for uranium (VI) ions preconcentration and quantification based on a synergistic combination of 4-(2-thiazolylazo)-resorcinol with 8 …

Y Kalyan, AK Pandey, GRK Naidu… - Spectrochimica Acta Part A …, 2009 - Elsevier
A membrane optode was developed utilizing the 8-hydroxyquinaldine (HQ) facilitated
preconcentration of UO22+ ions and subsequent colored complex formation of UO22+ with …

Characterization of a new uranyl selective bulk optode; utilizing synergistic effect in optical sensor

V Zare-Shahabadi, M Akhond, J Tashkhourian… - Sensors and Actuators B …, 2009 - Elsevier
A new optical sensor is fabricated for determination of uranyl ion. The optode membrane is
prepared by incorporation of 1-(2-pyridylazo)-2-naphtol (PAN), tri-n-octyl phosphine oxide …

Selective spectrophotometric method for the determination of uranium (VI)

BV Kadam, B Maiti, RM Sathe - Analyst, 1981 - pubs.rsc.org
Results For 100 pg of uranium (V1) in the presence of 2 ml of 0.1 M DPTA solution, colour
saturation was achieved with 1.0 ml of 0.1% arsenazo I11 solution at pH 5.5. The …

Novel PVC membrane bulk optical sensor for determination of uranyl ion

S Sadeghi, S Doosti - Sensors and Actuators B: Chemical, 2008 - Elsevier
A new bulk optical sensor, incorporating Piroxicam as a cation recognition and Alizarin as a
co-ionophore is reported for determination of trace amounts of uranyl ions (UO22+). The …

PVC membrane based potentiometric sensors for uranium determination

SSM Hassan, MM Ali, AMY Attawiya - Talanta, 2001 - Elsevier
Two novel uranyl PVC matrix membrane sensors responsive to uranyl ion are described.
The first sensor incorporates tris (2-ethylhexyl) phosphate (TEHP) as both electroactive …

Uranyl ion-selective optode based on neutral ionophores

M Lerchi, E Reitter, W Simon - Fresenius' journal of analytical chemistry, 1994 - Springer
An optical sensor (optode) is described based on a plasticized poly (vinyl chloride)(PVC)
bulk membrane incorporating an uranyl ion-selective ionophore, an H+-selective …

Absorptiometric determination of microgram amounts of uranium with Rhodamine B

HHP Moeken, WAH Van Neste - Analytica Chimica Acta, 1967 - Elsevier
Uranium (VI) can be extracted as a complex with rhodamine B into a benzeneetherhexone
solvent from a benzoate buffered solution. Optimum conditions for the colour development …

Spectrophotometric determination of uranium with arsenazo-III in perchloric acid

MH Khan, P Warwick, N Evans - Chemosphere, 2006 - Elsevier
A short, sensitive and reliable spectrophotometric method, which has advantages over all
known “wet chemistry” methods for uranium determination with regard to tolerance to …