Approximate reconstruction of attenuation map in SPECT imaging
AV Bronnikov - IEEE Transactions on Nuclear Science, 1995 - ieeexplore.ieee.org
The influence of linear attenuation presents certain difficulties for quantitative single-photon
emission computed tomography (SPECT) in medical imaging. To apply an attenuation …
emission computed tomography (SPECT) in medical imaging. To apply an attenuation …
Correction of nonuniform attenuation and image fusion in SPECT imaging by means of separate X-ray CT
T Kashiwagi, K Yutani, M Fukuchi, H Naruse… - Annals of nuclear …, 2002 - Springer
Improvements in image quality and quantitation measurement, and the addition of detailed
anatomical structures are important topics for single-photon emission tomography (SPECT) …
anatomical structures are important topics for single-photon emission tomography (SPECT) …
Simultaneous compensation for attenuation, scatter and detector response for SPECT reconstruction in three dimensions
Z Liang, TG Turkington, DR Gilland… - Physics in Medicine …, 1992 - iopscience.iop.org
A three-dimensional reconstruction method for simultaneous compensation of attenuation,
scatter and distance-dependent detector response for single photon emission computed …
scatter and distance-dependent detector response for single photon emission computed …
A differential attenuation method for simultaneous estimation of SPECT activity and attenuation distributions
MS Kaplan, DR Haynor, H Vija - IEEE Transactions on Nuclear …, 1999 - ieeexplore.ieee.org
A penalized weighted least squares (PWLS) reconstruction algorithm is described that
simultaneously estimates activity and attenuation distributions from emission sinogram data …
simultaneously estimates activity and attenuation distributions from emission sinogram data …
Simultaneous Tc-99m/Tl-201 imaging using energy-based estimation of the spatial distributions of contaminant photons
SC Moore, RJ English, C Syravanh… - IEEE transactions on …, 1995 - ieeexplore.ieee.org
The advantages of simultaneous acquisition of Tc-99m and Tl-201 myocardial perfusion
SPECT images can be fully realized only if the effects of the Tc-99m agent can be accurately …
SPECT images can be fully realized only if the effects of the Tc-99m agent can be accurately …
Quantitative image reconstruction with weighted backprojection for single photon emission computed tomography
E Tanaka - 1983 - journals.lww.com
A new method of image reconstruction for single photon emission computed tomography is
presented. The method is basically a filtered backprojection with some modifications. The …
presented. The method is basically a filtered backprojection with some modifications. The …
SPECT: Single photon emission computed tomography
RJ Jaszczak, RE Coleman… - IEEE Transactions on …, 1980 - ieeexplore.ieee.org
Interest in single photon emission computed tomography (SPECT) has been renewed as a
result of the successful application of transmission (x-ray) CT to diagnostic radiology. Many …
result of the successful application of transmission (x-ray) CT to diagnostic radiology. Many …
A 3D model of non-uniform attenuation and detector response for efficient iterative reconstruction in SPECT
DR Gilland, RJ Jaszczak, H Wang… - Physics in medicine …, 1994 - iopscience.iop.org
A 3D physical model for iterative reconstruction in SPECT. has been developed and applied
to experimental data. The model incorporates nonuniform attenuation using reconstructed …
to experimental data. The model incorporates nonuniform attenuation using reconstructed …
Attenuation correction in cardiac positron emission tomography and single-photon emission computed tomography
SL Bacharach, I Buvat - Journal of Nuclear Cardiology, 1995 - Springer
Quantitation in cardiac positron emission tomography (PET) and single-photon emission
computed tomography (SPECT) depends on being able to correct for several physical …
computed tomography (SPECT) depends on being able to correct for several physical …
Local threshold for segmented attenuation correction of PET imaging of the thorax
M Xu, WK Luk, PD Cutler… - IEEE Transactions on …, 1994 - ieeexplore.ieee.org
A local threshold for segmented attenuation correction technique has been developed for
positron emission tomography using short (2-3 minutes) post-injection transmission scans …
positron emission tomography using short (2-3 minutes) post-injection transmission scans …