[PDF][PDF] Wind response control of 76-storey benchmark building with distributed multiple tuned mass dampers
S Elias, V Matsagar - Journal of Wind and Engineering, 2014 - academia.edu
Wind response control of a 76-storey benchmark building installed with distributed multiple
tuned mass dampers (MTMDs) is investigated. The performance of the distributed MTMDs is …
tuned mass dampers (MTMDs) is investigated. The performance of the distributed MTMDs is …
Distributed multiple tuned mass dampers for wind vibration response control of high‐rise building
S Elias, V Matsagar - Journal of Engineering, 2014 - Wiley Online Library
Multiple tuned mass dampers (MTMDs) distributed along height of a high‐rise building are
investigated for their effectiveness in vibration response control. A 76‐storey benchmark …
investigated for their effectiveness in vibration response control. A 76‐storey benchmark …
Dynamic response control of a wind-excited tall building with distributed multiple tuned mass dampers
S Elias, V Matsagar, TK Datta - International Journal of Structural …, 2019 - World Scientific
Dynamic response control of a wind-excited tall building installed with distributed multiple
tuned mass dampers (d-MTMDs) is presented. The performance of d-MTMDs is compared …
tuned mass dampers (d-MTMDs) is presented. The performance of d-MTMDs is compared …
Optimum multiple tuned mass dampers for the wind excited benchmark building
VB Patil, RS Jangid - Journal of Civil Engineering and Management, 2011 - Taylor & Francis
The performance of multiple tuned mass dampers (MTMD) installed at the top floor of the
wind excited benchmark building under across wind loads is investigated. The performance …
wind excited benchmark building under across wind loads is investigated. The performance …
Wind response control of tall buildings with a tuned mass damper
S Elias, V Matsagar - Journal of Building Engineering, 2018 - Elsevier
Wind response control of tall buildings installed with a tuned mass damper (TMD) is
investigated. The performance of a TMD installed at the topmost floor of a 76-storey …
investigated. The performance of a TMD installed at the topmost floor of a 76-storey …
Vertically distributed multiple tuned mass dampers in tall buildings: performance analysis and preliminary design
KS Moon - The Structural Design of Tall and Special Buildings, 2010 - Wiley Online Library
This paper investigates the structural performance of vertically distributed multiple tuned
mass dampers (MTMDs), which can save valuable occupiable space near the top of tall …
mass dampers (MTMDs), which can save valuable occupiable space near the top of tall …
Study on wind-induced vibration control of linked high-rise buildings by using TMDI
Due to the aerodynamic interference of two closely-spaced linked high-rise buildings, large
out-of-phase vibrations of two buildings may be induced at across-wind direction. Tuned …
out-of-phase vibrations of two buildings may be induced at across-wind direction. Tuned …
Effect of tuned mass damper in wind‐induced response of “V” plan‐shaped tall building
S Bhattacharya, SK Dalui - The Structural Design of Tall and …, 2022 - Wiley Online Library
In this study, a “V” plan‐shaped building with single tuned mass damper (STMD) and
multiple tuned mass damper (MTMD) is analyzed in alongwind and crosswind direction …
multiple tuned mass damper (MTMD) is analyzed in alongwind and crosswind direction …
Seismic control of tall buildings using vertically distributed multiple tuned mass dampers
A Akhlagh Pasand, SM Zahrai - The Structural Design of Tall …, 2024 - Wiley Online Library
Tuned mass damper (TMD) is a seismic vibration control device used to reduce wind and
seismic vibrations of structures. Although TMD is attractive to many researchers due to its …
seismic vibrations of structures. Although TMD is attractive to many researchers due to its …
Wind response control of tall buildings with flexible foundation using tuned mass dampers
S Elias, V Matsagar - … for natural hazards: modeling, simulation, and …, 2018 - ascelibrary.org
Wind response control of tall buildings on flexible foundation using multiple tuned mass
dampers (MTMDs) is studied. The MTMDs are installed at the top of the reinforced concrete …
dampers (MTMDs) is studied. The MTMDs are installed at the top of the reinforced concrete …