Peripheral MR angiography

K Ho, T Leiner, MW De Haan… - European radiology, 1999 - Springer
Atherosclerotic disease of the lower extremities is a common disorder in western society. Its
debilitating nature calls for accurate diagnosis and treatment. The gold standard for …

MR angiography in the evaluation of atherosclerotic peripheral vascular disease

NM Rofsky, MA Adelman - Radiology, 2000 - pubs.rsna.org
Magnetic resonance (MR) angiography of lower extremity occlusive vascular disease has
evolved into a feasible diagnostic imaging option. The previous emphasis on time-of-flight …

High spatial and temporal resolution imaging of the arterial vasculature of the lower extremity with contrast enhanced MR angiography

PM Mostardi, CR Haider, JF Glockner… - Clinical …, 2011 - Wiley Online Library
Vascular imaging can be essential in the diagnosis, monitoring, and planning and
assessment of treatment of patients with peripheral vascular disease. The purpose of this …

Whole-body MRA

H Kramer, HH Quick, B Tombach, SO Schoenberg… - European …, 2008 - Springer
Vascular diseases today constitute a serious health burden, ranking atherosclerosis as
number one in the morbidity and mortality statistics of developed countries, with a still …

Noncontrast peripheral MRA with spiral echo train imaging

SW Fielden, JP Mugler III, KD Hagspiel… - Magnetic …, 2015 - Wiley Online Library
Purpose To develop a spin echo train sequence with spiral readout gradients with improved
artery–vein contrast for noncontrast angiography. Theory Venous T2 becomes shorter as the …

Peripheral magnetic resonance angiography (MRA) with continuous table movement at 3.0 T: initial experience compared with step-by-step MRA

H Kramer, M Zenge, P Schmitt, C Glaser… - Investigative …, 2008 - journals.lww.com
Purpose: To compare a standard step-by-step and a newly developed continuous table
movement (CTM) technique for peripheral magnetic resonance angiography (MRA) at a 3.0 …

Technical aspects of contrast-enhanced MR angiography: current status and new applications

SJ Riederer, EG Stinson, PT Weavers - Magnetic Resonance in …, 2018 - jstage.jst.go.jp
This article is based on a presentation at the meeting of the Japanese Society of Magnetic
Resonance in Medicine in September 2016. The purpose is to review the technical …

High spatial resolution whole-body MR angiography featuring parallel imaging: initial experience

HH Quick, FM Vogt, S Madewald… - RöFo-Fortschritte auf …, 2004 - thieme-connect.com
Ziel: Einsatz paralleler Akquisitionstechniken (PAT) zur Erhöhung der räumlichen Auflösung
bei der kontrastverstärkten Multistation-Ganzkörper-MR-Angiographie (MRA) mit einer …

Unenhanced MR angiography

M Backens, B Schmitz - Magnetic Resonance Angiography: Techniques …, 2005 - Springer
In conventional x-ray digital subtraction angiography (DSA), administration of contrast agent
is necessary in order to depict blood vessels. After arterial catheterization and injection of an …

Triple-TWIST MRA: high spatial and temporal resolution MR angiography of the entire peripheral vascular system using a time-resolved 4D MRA technique

S Kinner, HH Quick, S Maderwald, P Hunold… - European …, 2013 - Springer
Objectives Multi-station contrast-enhanced magnetic resonance angiography (MRA) is
considered as the imaging investigation of first choice in patients suffering from peripheral …