Three‐dimensional assessment of lung tissue density using a clinical ultrashort echo time at 3 tesla: a feasibility study in healthy subjects

M Lederlin, Y Crémillieux - Journal of Magnetic Resonance …, 2014 - Wiley Online Library
Purpose To implement and assess the performance of three‐dimensional (3D) ultra‐short
echo (UTE) time for evaluating lung tissue density changes induced by gravity dependence …

Ultrashort echo time (UTE) MRI of the lung: assessment of tissue density in the lung parenchyma

O Togao, R Tsuji, Y Ohno, I Dimitrov… - Magnetic resonance …, 2010 - Wiley Online Library
Nonuniform disruption of lung architecture is usually assessed by CT, which carries potential
radiation risk. Here we report our use of a three‐dimensional ultrashort echo time MR …

Simultaneous evaluation of lung anatomy and ventilation using 4D respiratory‐motion‐resolved ultrashort echo time sparse MRI

LI Feng, J Delacoste, D Smith… - Journal of Magnetic …, 2019 - Wiley Online Library
Background Computed tomography (CT) and spirometry are the current standard methods
for assessing lung anatomy and pulmonary ventilation, respectively. However, CT provides …

2D ultrashort echo‐time functional lung imaging

A Balasch, P Metze, K Stumpf, M Beer… - Journal of Magnetic …, 2020 - Wiley Online Library
Background Imaging of the lung by MRI is challenging due to the intrinsic low proton density
and rapid T2* relaxation. MRI methods providing lung parenchyma and function are in …

Comparison of lung imaging using three-dimensional ultrashort echo time and zero echo time sequences: preliminary study

K Bae, KN Jeon, MJ Hwang, JS Lee, JY Ha, KH Ryu… - European …, 2019 - Springer
Objective To determine the feasibility of using high-resolution volumetric zero echo time
(ZTE) sequence in routine lung magnetic resonance imaging (MRI) and compare free …

Quantitative MRI measurement of lung density must account for the change in T with lung inflation

RJ Theilmann, TJ Arai, A Samiee… - Journal of Magnetic …, 2009 - Wiley Online Library
Purpose To evaluate lung water density at three different levels of lung inflation in normal
lungs using a fast gradient echo sequence developed for rapid imaging. Materials and …

Three‐dimensional T1 and T2* mapping of human lung parenchyma using interleaved saturation recovery with dual echo ultrashort echo time imaging (ITSR‐DUTE)

ND Gai, AA Malayeri… - Journal of Magnetic …, 2017 - Wiley Online Library
Purpose To develop and assess a new technique for three‐dimensional (3D) full lung T1
and T2* mapping using a single free breathing scan during a clinically feasible time …

Ultra‐short echo‐time pulmonary MRI: Evaluation and reproducibility in COPD subjects with and without bronchiectasis

W Ma, K Sheikh, S Svenningsen, D Pike… - Journal of Magnetic …, 2015 - Wiley Online Library
Background To evaluate ultra‐short‐echo‐time (UTE) MRI pulmonary signal‐intensity
measurements and reproducibility in chronic obstructive pulmonary disease (COPD) …

Murine pulmonary imaging at 7T: and T1 with anisotropic UTE

J Guo, X Cao, ZI Cleveland… - Magnetic resonance in …, 2018 - Wiley Online Library
Purpose To measure the and T1 of mouse lung at 7T via anisotropic‐resolution radial
ultrashort echo‐time imaging with ellipsoidal k‐space coverage. Methods Ellipsoidal field‐of …

Functional MRI of the lungs using single breath-hold and self-navigated ultrashort echo time sequences

JF Heidenreich, S Veldhoen, C Metz… - Radiology …, 2020 - pubs.rsna.org
Purpose To evaluate three-dimensional (3D) ultrashort echo time (UTE) MRI regarding
image quality and suitability for functional image analysis using gradient-echo sequences in …