Measurements of doses from photon beam irradiation and scattered neutrons in an anthropomorphic phantom model of prostate cancer: a comparison between …

A Kowalik, W Jackowiak, J Malicki, M Skórska… - Nukleonika, 2017 - sciendo.com
Introduction. The rapid development of new radiotherapy technologies, such as intensity
modulated radiotherapy (IMRT) or tomotherapy, has resulted in the capacity to deliver a …

Peripheral Photon Doses from Different Techniques Delivered in Prostate Radiotherapy: Experimental Measurements and TPS Calculations.

H Azab, R Moussa… - Arab Journal of Nuclear …, 2020 - ajnsa.journals.ekb.eg
Advanced techniques and modalities in delivering radiotherapy improved the ability of
delivering higher tumor doses while minimizing dose to the critical organs. The aim of this …

Calculated organ doses from selected prostate treatment plans using Monte Carlo simulations and an anatomically realistic computational phantom

B Bednarz, C Hancox, XG Xu - Physics in Medicine & Biology, 2009 - iopscience.iop.org
There is growing concern about radiation-induced second cancers associated with radiation
treatments. Particular attention has been focused on the risk to patients treated with intensity …

In-Phantom Peripheral Organ Doses from Prostate Irradiation Using 18 MV External Beam Radiotherapy Measured with 6LiF:Mg,Cu,P & 7LiF:Mg,Cu,P Glass-Rod …

R Takam, E Bezak, E Yeoh, G Liu - … 7-12, 2009, Munich, Germany: Vol. 25 …, 2009 - Springer
A radiation dosimetry technique based on pairs of 6 LiF: Mg, Cu, P and 7 LiF: Mg, Cu, P
glass-rod TLDs was developed for measuring peripheral photon and neutron doses in the …

Peripheral photon and neutron doses from prostate cancer external beam irradiation

E Bezak, R Takam, LG Marcu - Radiation protection dosimetry, 2015 - academic.oup.com
Peripheral photon and neutron doses from external beam radiotherapy (EBRT) are
associated with increased risk of carcinogenesis in the out-of-field organs; thus, dose …

Dosimetric evaluation in brachytherapy and teletherapy for prostate cancer using Monte Carlo simulation and anatomically realistic virtual anthropomorphic phantom

WS Santos, DAA Xavier, CJ Santos, LP Neves… - Radiation Physics and …, 2023 - Elsevier
The benefits that radiotherapy provides to the patient are unquestionable. However, there is
growing concern about the increased risk of radiation-induced secondary cancer and the …

In vivo and phantom measurements of the secondary photon and neutron doses for prostate patients undergoing IMRT

CS Reft, R Runkel‐Muller… - Medical physics, 2006 - Wiley Online Library
For intensity modulated radiation therapy (IMRT) treatments photons are typically used,
however, for deep seated tumors in the pelvic region, higher photon energies are …

Clinical simulations of prostate radiotherapy using BOMAB-like phantoms: results for neutrons

A Di Fulvio, L Tana, M Caresana, E D'Agostino… - Radiation …, 2013 - Elsevier
This paper presents in-phantom photoneutron equivalent doses induced by external
radiotherapy, these are necessary to assess organ-averaged equivalent doses to derive the …

MC estimation of out-of-field organ doses from scattered photons, photoneutrons, and capture gamma rays in prostate radiation therapy

M Mohammadzadeh, A Mesbahi - Nuclear Technology and …, 2010 - doiserbia.nb.rs
In the current study, the out-of-field organ and effective dose for external radiation therapy of
prostate cancer was estimated by the MCNPX Monte Carlo code and a mathematical …

Clinical simulations of prostate radiotherapy using BOMAB-like phantoms: results for photons

S Miljanić, I Bessieres, JM Bordy, F d'Errico… - Radiation …, 2013 - Elsevier
In this part of work carried out by Working Group 9 (Radiation Protection Dosimetry in
Medicine) of the European Radiation Dosimetry Group (EURADOS), water tank experiments …