[HTML][HTML] Noninvasive assessment of aortic pulse wave velocity by the brachial occlusion-cuff technique: Comparative study

V Fabian, L Matera, K Bayerova, J Havlik, V Kremen… - Sensors, 2019 - mdpi.com
Cardiovascular diseases are one of most frequent cause of morbidity and mortality in the
world. There is an emerging need for integrated, non-invasive, and easy-to-use clinical tools …

Oscillometric estimation of aortic pulse wave velocity: comparison with intra-aortic catheter measurements

B Hametner, S Wassertheurer, J Kropf… - Blood pressure …, 2013 - journals.lww.com
Objectives Recently, a novel method to estimate aortic pulse wave velocity (aPWV)
noninvasively from an oscillometric single brachial cuff waveform reading has been …

Measurement of central aortic pulse pressure: noninvasive brachial cuff-based estimation by a transfer function vs. a novel pulse wave analysis method

HM Cheng, SH Sung, YT Shih… - American journal of …, 2012 - academic.oup.com
Background The prognostic value of central aortic pulse pressure (PP-C) may have been
underestimated due to its measurement inaccuracy. We aimed to investigate the accuracy of …

Performance of pulse wave velocity measured using a brachial cuff in a community setting

D Nunan, S Fleming, B Hametner… - Blood pressure …, 2014 - journals.lww.com
Background We have previously reported that estimation of central blood pressure (BP) and
augmentation using an automated oscillometric device are robust and feasible in a …

Numerical validation of a new method to assess aortic pulse wave velocity from a single recording of a brachial artery waveform with an occluding cuff

B Trachet, P Reymond, J Kips, A Swillens… - Annals of biomedical …, 2010 - Springer
Recently a new method has been proposed as a tool to measure arterial pulse wave velocity
(PWV), a measure of the stiffness of the large arteries and an emerging parameter used as …

[HTML][HTML] Comparison of invasive and brachial cuff-based noninvasive measurements for the assessment of blood pressure amplification

A Nakagomi, S Okada, T Shoji, Y Kobayashi - Hypertension Research, 2017 - nature.com
Our aim was to assess the discrepancy in the blood pressure amplification (BPA) value
defined as the aortic-to-brachial increase in systolic BP (SBP) between invasive and …

Accelerometric patch probe for cuffless blood pressure evaluation from carotid local pulse wave velocity: Design, development, and in vivo experimental study

R Arathy, PM Nabeel, J Joseph… - Biomedical Physics & …, 2019 - iopscience.iop.org
Objective: In this work, we demonstrate an accelerometric patch probe and associated
measurement system for local pulse wave velocity (PWV) measurement and its application …

Validation of a Suprasystolic Cuff System for Static and Dynamic Representation of the Central Pressure Waveform

A Tamborini, M Gharib - Journal of the American Heart Association, 2024 - Am Heart Assoc
Background Noninvasive pulse waveform analysis is valuable for central cardiovascular
assessment, yet controversies persist over its validity in peripheral measurements. Our …

Impact of a cuff‐based device calibration method on the agreement between invasive and noninvasive aortic and brachial pressure

D Bia, F Salazar, L Cinca, M Gutierrez… - Clinical Physiology …, 2024 - Wiley Online Library
Introduction Brachial cuff‐based methods are increasingly used to estimate aortic systolic
blood pressure (aoSBP). However, there are several unresolved issues. Aims to determine …

Oscillometric estimation of central blood pressure: validation of the Mobil-O-Graph in comparison with the SphygmoCor device

W Weiss, C Gohlisch, C Harsch-Gladisch… - Blood pressure …, 2012 - journals.lww.com
Background Hypertension is a major risk factor for a wide range of cardiovascular diseases
and is typically identified by measuring blood pressure (BP) at the brachial artery. Although …