The benefit of a second burst antitachycardia sequence for fast ventricular tachycardia in patients with implantable cardioverter defibrillators
I Anguera, P Dallaglio, X Sabate… - Pacing and Clinical …, 2014 - Wiley Online Library
Background In patients with implantable cardioverter defibrillators (ICDs), an empirical burst
of antitachycardia pacing (ATP) is moderately effective in terminating fast ventricular …
of antitachycardia pacing (ATP) is moderately effective in terminating fast ventricular …
Shock reduction with multiple bursts of antitachycardia pacing therapies to treat fast ventricular tachyarrhythmias in patients with implantable cardioverter defibrillators …
I Anguera, P Dallaglio… - Journal of …, 2015 - Wiley Online Library
Multiple Bursts for Fast Ventricular Tachycardia Introduction An empirical sequence of burst
antitachycardia pacing (ATP) is effective in terminating fast ventricular tachycardias (FVT) in …
antitachycardia pacing (ATP) is effective in terminating fast ventricular tachycardias (FVT) in …
A randomized study to compare ramp versus burst antitachycardia pacing therapies to treat fast ventricular tachyarrhythmias in patients with implantable cardioverter …
MM Gulizia, L Piraino, M Scherillo… - Circulation …, 2009 - Am Heart Assoc
Background—In patients with implantable cardioverter-defibrillators (ICDs), antitachycardia
pacing (ATP) is highly effective in terminating fast ventricular tachycardias (FVTs) and lowers …
pacing (ATP) is highly effective in terminating fast ventricular tachycardias (FVTs) and lowers …
Safety and efficacy of programming a high number of antitachycardia pacing attempts for fast ventricular tachycardia: a prospective study
RP Martins, H Blangy, L Muresan, L Freysz… - Europace, 2012 - academic.oup.com
Aims Little is known about the optimal number of antitachycardia pacing (ATP) attempts to
programme in the fast ventricular tachycardia (FVT) zone. We sought to analyse the long …
programme in the fast ventricular tachycardia (FVT) zone. We sought to analyse the long …
Discriminatory therapy for very fast ventricular tachycardia in patients with implantable cardioverter defibrillators
G Sivagangabalan, S Eshoo, VE Eipper… - Pacing and clinical …, 2008 - Wiley Online Library
Objectives: We assessed the efficacy of antitachycardia pacing (ATP) and low‐energy (5J)
shock for very fast ventricular tachycardia (VFVT), cycle length 200–250 ms, in patients with …
shock for very fast ventricular tachycardia (VFVT), cycle length 200–250 ms, in patients with …
Prospective randomized multicenter trial of empirical antitachycardia pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable …
MS Wathen, PJ DeGroot, MO Sweeney, AJ Stark… - Circulation, 2004 - Am Heart Assoc
Background—Successful antitachycardia pacing (ATP) terminates ventricular tachycardia
(VT) up to 250 bpm without the need for painful shocks in implantable cardioverter …
(VT) up to 250 bpm without the need for painful shocks in implantable cardioverter …
Efficacy of Anti-Tachycardia Pacing for Terminating Fast Ventricular Tachycardia in Japanese Implantable Cardioverter Defibrillator Patients–Primary Results of the …
T Watanabe, K Inoue, K Kashiwase, T Mine… - Circulation …, 2014 - jstage.jst.go.jp
Background: Anti-tachycardia pacing (ATP) delivered by implantable cardioverter
defibrillators (ICD) safely avoids painful shocks with minimum risk of tachycardia …
defibrillators (ICD) safely avoids painful shocks with minimum risk of tachycardia …
Prospective multicenter randomized trial of fast ventricular tachycardia termination by prolonged versus conventional anti-tachyarrhythmia burst pacing in implantable …
M Santini, M Lunati, P Defaye, J Mermi… - Journal of interventional …, 2010 - Springer
Purpose The purpose of the trial was to quantify and compare the efficacy of two different
sequences of burst anti-tachycardia pacing (ATP) strategies for the termination of fast …
sequences of burst anti-tachycardia pacing (ATP) strategies for the termination of fast …
Antitachycardia pacing for very fast ventricular tachycardia and low-energy shock for ventricular arrhythmias in patients with implantable defibrillators
Implantable cardioverter-defibrillator therapy in the form of high-energy shock (HES) is
associated with adverse effects. This study evaluated an alternative therapy to HES …
associated with adverse effects. This study evaluated an alternative therapy to HES …
Shock reduction with antitachycardia pacing before and during charging for fast ventricular tachycardias in patients with implantable defibrillators
PD Dallaglio, I Anguera, JBM Ferrer, L Pérez… - Revista Española de …, 2018 - Elsevier
Introduction and objectives Fast ventricular tachycardias in the ventricular fibrillation zone in
patients with an implantable cardioverter-defibrillator are susceptible to antitachycardia …