Standards for pH measurements in isotonic saline media of ionic strength I= 0.16
RG Bates, CA Vega, DR White - Analytical Chemistry, 1978 - ACS Publications
Evidence Is presented that pH measurements of blood plasma and otherclinical media at an
Ionic strength (I) of 0.16 vs. the NBS standards may Involve residual liquid-junction errors …
Ionic strength (I) of 0.16 vs. the NBS standards may Involve residual liquid-junction errors …
Establishing the direct-potentiometric" normal" range for Na/K: residual liquid junction potential and activity coefficient effects.
JD Czaban, AD Cormier, KD Legg - Clinical chemistry, 1982 - academic.oup.com
The observed reference ranges for sodium and potassium as determined by direct
potentiometry vary from instrument to instrument, depending on the composition of the …
potentiometry vary from instrument to instrument, depending on the composition of the …
Tris/Tris· HCl: a standard buffer for use in the physiologic pH range
RA Durst, BR Staples - Clinical Chemistry, 1972 - academic.oup.com
A buffer solution containing tris (hydroxymethyl)-aminomethane (0.01667 mol/kg) and its
hydrochloride salt (0.0500 mol/kg) is proposed as a pH standard for the physiologically …
hydrochloride salt (0.0500 mol/kg) is proposed as a pH standard for the physiologically …
pH determination in body fluids using a cell with an isotonic sodium chloride bridge
AH Maas - Journal of Applied Physiology, 1971 - journals.physiology.org
MAAS, AHJ pH determination in body Juids using a cell with an isotonic sodium chloride
bridge. J. Appl. Physiol. 30 (2): 24% 250. 1971.-By pH measurements in plasma and blood …
bridge. J. Appl. Physiol. 30 (2): 24% 250. 1971.-By pH measurements in plasma and blood …
Direct potentiometric measurement of sodium and potassium in whole blood.
JH Ladenson - Clinical chemistry, 1977 - academic.oup.com
I compared results for sodium and potassium in whole blood and plasma as measured with
a newly available potentiometric analyzer, the" Orion SS-30". No significant difference was …
a newly available potentiometric analyzer, the" Orion SS-30". No significant difference was …
[引用][C] Determination of pH in concentrated salt solutions
EW Baumann - Analytica Chimica Acta, 1973 - Elsevier
The presence of molar concentrations of dissolved salts causes errors m pH values
measured with the glass electrode m a'cell wrth liquid Junction that 1s cahbrated with …
measured with the glass electrode m a'cell wrth liquid Junction that 1s cahbrated with …
[HTML][HTML] A standard for the measurement of the pH of blood and other physiological media
VE Bower, M Paabo, RG Bates - Journal of Research of the …, 1961 - ncbi.nlm.nih.gov
A buffer solution containing potassium dihydrogen phosphate (0.008695 molal) and
disodium hydrogen phosphate (0.03043 molal) is proposed as a pH standard for the …
disodium hydrogen phosphate (0.03043 molal) is proposed as a pH standard for the …
pH Standard for Blood and Other Physiologic Media
VE Bower, M Paabo, RG Bates - Clinical Chemistry, 1961 - academic.oup.com
A new National Bureau of Standards pH standard, intended to facilitate measurements of the
pH of blood and other physiologic media in the range 7-8, is announced. The new buffer …
pH of blood and other physiologic media in the range 7-8, is announced. The new buffer …
pH measurement in concentrated alkaline solutions
S Licht - Analytical chemistry, 1985 - ACS Publications
In this study, the rangeof glass electrode aqueous pH mea-surements Is extended to pH
17.6. Traditional problems as-sociated with high pH measurement, Including liquid Junction …
17.6. Traditional problems as-sociated with high pH measurement, Including liquid Junction …
pH-Metric log P. 3. Glass electrode calibration in methanol-water, applied to pKa determination of water-insoluble substances
A Avdeef, JEA Comer, SJ Thomson - Analytical Chemistry, 1993 - ACS Publications
A serle· of semlaqueous HCIsolutions of known concentration, containing 0.1 M KN03 (as
Ionic strength adjuster) and 0-70 wt% methanol, was titrated at 21, 25, and 37 C with …
Ionic strength adjuster) and 0-70 wt% methanol, was titrated at 21, 25, and 37 C with …