Transcatheter closure of secundum atrial septal defects with the new self-centering Amplatzer Septal Occluder

G Fischer, HH Kramer, J Stieh, P Harding… - European heart …, 1999 - academic.oup.com
Aims The study was set up to find out whether a new self-centering prosthesis for
transcatheter closure of secundum atrial septal defects could overcome the disadvantages …

[引用][C] Selection of patients with secundum atrial septal defects for transcather device closure

SA Qureshi - European Heart Journal, 2000 - academic.oup.com
Over the last two decades numerous attempts have been made at transcatheter closure of
secundum atrial septal defects using several different devices. The progress has been slow …

Initial clinical results with the Amplatzer septal occluder--a self-centering double disc for occlusion of atrial septal defects

F Berger, P Ewert, B Stiller, I Daehnert… - Zeitschrift fur …, 1998 - europepmc.org
[Initial clinical results with the Amplatzer septal occluder--a self-centering double disc for
occlusion of atrial septal defects]. - Abstract - Europe PMC Sign in | Create an account https://orcid.org …

Catheter closure of secundum atrial septal defects.

MP O'Laughlin - Texas Heart Institute Journal, 1997 - ncbi.nlm.nih.gov
Catheter occlusion of atrial septal defects has its roots in the 1950s, with early devices being
implanted during closed-heart surgery without cardiopulmonary bypass. For the past 20 …

[引用][C] StarFlex ASD closure: deployment, techniques, equipment

G HAUSDORF - Journal of Interventional Cardiology, 2001 - Wiley Online Library
Although the low surgical mortality and morbidity associated with closure of atrial septal
defect (ASD) is generally accepted, transcatheter closure is becoming an attractive …

Interventional occlusion of atrial septum defects larter than 20 mm in diameter

F Berger, P Ewert, I Dähnert, B Stiller… - Zeitschrift fur …, 2000 - europepmc.org
Method The stretched diameter of the ASD was measured by inflating a sizing balloon within
the defect until an indentation in the circumference in the balloon could be observed. An …

Percutaneous catheter closure of secundum atrial septal defects: a review.

MR Ebeid - The Journal of invasive cardiology, 2002 - europepmc.org
Attempts at catheter closure of atrial septal defects began over 3 decades ago. Several
devices have been designed attempting to achieve this objective safely and effectively …

Summary and Comparison of Atrial Septal Defect Closure Devices.

PS Rao - Current Interventional Cardiology Reports, 2000 - europepmc.org
A large number of atrial septal defect (ASD) closure devices have been investigated in an
attempt to develop a nonsurgical, transvenous method of occlusion of ASD. Some of the …

Closure of secundum atrial septal defects with the Amplatzer septal occluder device: techniques and problems

RW Harper, PM Mottram… - Catheterization and …, 2002 - Wiley Online Library
Percutaneous transvenous closure of atrial septal defects (ASDs) has become feasible in
recent years, as later‐generation devices have largely overcome initial difficulties in device …

Transcatheter atrial septal defect closure: modified balloon sizing technique to avoid overstretching the defect and oversizing the Amplatzer septal occluder

KM Carlson, H Justino, RE O'Brien… - Catheterization and …, 2005 - Wiley Online Library
The objective of this study was to evaluate a new technique of sizing atrial septal defects
(ASDs) for transcatheter device closure. ASD closure using the Amplatzer septal occluder …