Dosimetry modeling for focal high-dose-rate prostate brachytherapy

J Mason, B Al-Qaisieh, P Bownes, D Thwaites, A Henry - Brachytherapy, 2014 - Elsevier
Purpose The dosimetry of focal high-dose-rate prostate brachytherapy was assessed. Dose
volume histogram parameters, robustness to source position errors, and Monte Carlo (MC) …

egs_brachy: a versatile and fast Monte Carlo code for brachytherapy

MJP Chamberland, REP Taylor… - Physics in Medicine …, 2016 - iopscience.iop.org
Abstract egs_brachy is a versatile and fast Monte Carlo (MC) code for brachytherapy
applications. It is based on the EGSnrc code system, enabling simulation of photons and …

[PDF][PDF] Radial dose functions of GZP6 intracavitary brachytherapy 60Co sources: treatment planning system versus Monte Carlo calculations

A Mesbahi - Iranian Journal of Radiation Research, 2008 - researchgate.net
Background: The Monte Carlo (MC) method is not only used for dose calculations around
brachytherapy sources but also for benchmarking treatment planning systems (TPS) …

Dosimetric characterization of radioactive sources employed in prostate cancer therapy

VO Zilio, OP Joneja, Y Popowski, R Chawla - Brachytherapy, 2004 - Elsevier
PURPOSE: Three types of radiation sources are employed currently in the radiation
treatment of prostate cancer, namely, external, implant, and high-dose-rate (HDR) sources …

AAPM TG‐43U1 formalism adaptation and Monte Carlo dosimetry simulations of multiple‐radionuclide brachytherapy sources

VE Nuttens, S Lucas - Medical physics, 2006 - Wiley Online Library
This paper presents a preliminary study on multiple‐radionuclide sources for brachytherapy.
An adaptation of the AAPM TG‐43U1 formalism is proposed in order to derive the dosimetry …

[PDF][PDF] American brachytherapy society prostate low-dose rate task group

GS Merrick, M Zelefsky… - Availabel at: http …, 2007 - americanbrachytherapy.org
• Dosimetry o Dosimetry in accordance with 2004 AAPM TG-43U1 methodology o 2-D
source characterization preferred only when source orientation is evident o The prescribed …

Quantifying the effect of seed orientation in postplanning dosimetry of low‐dose‐rate prostate brachytherapy

CA Collins Fekete, M Plamondon, AG Martin… - Medical …, 2014 - Wiley Online Library
Purpose: Radioactive seed orientations are usually ignored in clinical brachytherapy
dosimetry for prostate implants. Associated with the anisotropic dose distribution of seeds …

[图书][B] MCNP5 Monte Carlo based dosimetry for the nucletron iridium-192 high dose-rate brachytherapy source with tissue heterogeneity corrections

R Herrera - 2012 - search.proquest.com
A Monte Carlo model has been developed using MCNP5 to simulate the Nucletron Ir-192
HDR source in order to investigate the influence of tissue heterogeneities on dose …

Validation of GPUMCD for low‐energy brachytherapy seed dosimetry

S Hissoiny, B Ozell, P Després, JF Carrier - Medical Physics, 2011 - Wiley Online Library
Purpose: To validate Gpumcd, a new package for fast Monte Carlo dose calculations based
on the GPU (graphics processing unit), as a tool for low‐energy single seed brachytherapy …

On the impact of absorbed dose specification, tissue heterogeneities, and applicator heterogeneities on Monte Carlo‐based dosimetry of Ir‐192, Se‐75, and Yb‐169 …

M Morcos, AN Viswanathan, SA Enger - Medical physics, 2021 - Wiley Online Library
Purpose The purpose of this study was to evaluate the impact of dose reporting schemes
and tissue/applicator heterogeneities for 192Ir‐, 75Se‐, and 169Yb‐based MRI‐guided …