Retention characteristics of attachment systems for implant overdentures

KH Chung, CY Chung, DR Cagna… - … : Implant, Esthetic and …, 2004 - Wiley Online Library
retention characteristics of various overdenture attachment systems commonly used to retain
overdentures to dental implants… × 13 mm Branemark implants placed in the canine regions. …

Attachment systems for implant retained overdentures: a literature review

T Trakas, K Michalakis, K Kang, H Hirayama - Implant dentistry, 2006 - journals.lww.com
… This problem becomes even greater because the choice as to which attachment to use is …
different attachments used routinely in implant-retained overdentures on: (1) implant survival …

[PDF][PDF] Attachment systems for mandibular two-implant overdentures: a review of in vitro investigations on retention and wear features

MV Swain - Int J Prosthodont, 2009 - academia.edu
… on retention or wear features of attachment systems specifically for use with mandibular
two-implant overdentures under … of the methodology used in evaluating the attachment systems. …

[HTML][HTML] Attachment systems for mandibular implant overdentures: a systematic review

HY Kim, JY Lee, SW Shin… - The journal of advanced …, 2012 - synapse.koreamed.org
implant overdentures until August, 2010 were selected if more than one type of overdenture
attachment … and the data on implant survival rate, prosthetic maintenance and complications, …

Comparison of retention and release periods for implant overdenture attachments.

VC Petropoulos, W Smith… - … & Maxillofacial Implants, 1997 - search.ebscohost.com
… This investigation studied two characteristics of the implant attachment system on an
implant-retained overdenture model: break load measurement, which is the measure of retention; …

Comparison of retention and stability of two implant-retained overdentures based on implant location

MD Scherer, EA McGlumphy, RR Seghi… - The Journal of prosthetic …, 2014 - Elsevier
implants and attachment systems on the retention and stability of … implant location on the
magnitude of force required to dislodge a simulated 2-implant-retained overdenture prosthesis. …

A comparison of three different attachment systems for mandibular two‐implant overdentures: One‐year report

WK Kleis, PW Kämmerer, S Hartmann… - Clinical implant …, 2010 - Wiley Online Library
… Though, the main point of interest in this study was on retention and stability of the mandibular
overdenture. In a 10-year randomized study, Naert and colleagues 30 could show the …

Evaluation of retention, wear, and maintenance of attachment systems for single-or two-implant-retained mandibular overdentures: a systematic review

R Wakam, A Benoit, KB Mawussi, C Gorin - Materials, 2022 - mdpi.com
Attachment systems (AS) enhance retention and stability by anchoring the overdentures to
implants… statement recommends the 2-implant-retained overdentures as the standard choice …

Implantretained partial overdenture with resilient attachments

I Chikunov, P Doan, F Vahidi - Journal of Prosthodontics, 2008 - Wiley Online Library
… This article discussed the implant-retained RPD using resilient attachments as a treatment
option for partial edentulism. The indications and contraindications as well as a thorough …

[PDF][PDF] Locator® attachment system for implant overdentures: a systematic review

A Miler, ARM Correia, JMC Rocha, JCR Campos… - …, 2017 - researchgate.net
implant-supported overdentures within the Locator retention … , their complications, maintenance
and patient satisfaction. … Testing the retention of attachments for implant overdentures