Grating interferometer based scanning setup for hard x-ray phase contrast imaging

C Kottler, F Pfeiffer, O Bunk, C Grünzweig… - Review of Scientific …, 2007 - pubs.aip.org
… is very often favorable when compared to a direct two-dimensional image acquisition. Here,
we report on an efficient scanning method for grating based x-ray phase contrast imaging

[HTML][HTML] Talbot-Lau x-ray phase-contrast setup for fast scanning of large samples

M Seifert, V Ludwig, S Kaeppler, F Horn, P Meyer… - Scientific reports, 2019 - nature.com
scanning setup which enables imaging of large samples. With this setup a maximal scanning
… An improved reconstruction algorithm concerning the scanning approach, which increases …

Mc3d: Motion contrast 3d scanning

N Matsuda, O Cossairt, M Gupta - 2015 IEEE International …, 2015 - ieeexplore.ieee.org
… For example, in point light scanning systems, every captured image has only one sensor …
For our 128 pixel line scanning setup this translates to a maximum resolvable scan rate of …

Resolution and contrast enhancement in laser scanning microscopy using dark beam imaging

H Dehez, M Piché, Y De Koninck - Optics express, 2013 - opg.optica.org
… These constraints limit the applicability of resolution improvement to various imaging
and contrast in laser scanning microscopy. SLAM microscopy relies on subtracting images

[HTML][HTML] Contrast enhancement for topographic imaging in confocal laser scanning microscopy

L Schnitzler, M Finkeldey, MR Hofmann, NC Gerhardt - Applied Sciences, 2019 - mdpi.com
… to the setup, thus our concept is applicable for all types of confocal microscopes. Furthermore,
we show the application of the contrast enhancement in imaging integrated circuits. …

[HTML][HTML] Zernike phase contrast in scanning microscopy with X-rays

C Holzner, M Feser, S Vogt, B Hornberger, SB Baines… - Nature physics, 2010 - nature.com
… 3a,b we show scanning images obtained in Zernike phase contrast and absorption contrast,
… lies in the simplicity of the set-up and straightforward correspondence of the image to the …

Tilted-grating approach for scanning-mode X-ray phase contrast imaging

C Arboleda, Z Wang, M Stampanoni - Optics Express, 2014 - opg.optica.org
… A scanning setup is a good solution for this issue, because it uses cheaper line instead of
large-area 2D detectors and, therefore, would require smaller gratings. In such a …

Experimental results from a preclinical X-ray phase-contrast CT scanner

A Tapfer, M Bech, A Velroyen… - Proceedings of the …, 2012 - National Acad Sciences
… developed a first preclinical phase-contrast CT scanner. This development represents an …
phase-contrast imaging to clinical settings, as all grating-based phase-contrast setups, which …

Slit‐scanning differential x‐ray phase‐contrast mammography: Proof‐of‐concept experimental studies

T Koehler, H Daerr, G Martens, N Kuhn… - Medical …, 2015 - Wiley Online Library
… Still there are two more important differences compared to the scanning setup by … -contrast
imaging on a clinical FFDM system by employing the inherent nature of the slit-scanning

An innovative digital imaging setup allowing a low‐dose approach to phase contrast applications in the medical field

A Olivo, F Arfelli, G Cantatore, R Longo… - Medical …, 2001 - Wiley Online Library
… in the next section, the sample scanning stage has been placed at a distance of … contrast
image quality in the vertical direction, ie, the direction along which the sample is scanned