Noninvasive quantification of T2 and concentrations of ascorbate and glutathione in the human brain from the same double‐edited spectra
… Asc) and glutathione (GSH) were measured from a single dataset of double‐edited spectra
that were … Spectra measured at all six TEs were summed to quantify the concentration in each …
that were … Spectra measured at all six TEs were summed to quantify the concentration in each …
New double quantum coherence filter for localized detection of glutathione in vivo
T Zhao, K Heberlein, C Jonas… - … in Medicine: An …, 2006 - Wiley Online Library
… the frequency and phase in the edited spectra based on simultaneously detected singlet
resonances. However, J-difference spectra are susceptible to subtraction errors due to patient …
resonances. However, J-difference spectra are susceptible to subtraction errors due to patient …
GSH and GABA decreases in IDH1-mutated low-grade gliomas detected by HERMES spectral editing at 3 T in vivo
… but may not necessarily lead to less actual glutathione, and we hypothesize the decrease of
… This study has shown that HERMES can be applied for the simultaneous detection of GABA …
… This study has shown that HERMES can be applied for the simultaneous detection of GABA …
Simultaneous spectral editing for γ-aminobutyric acid and taurine using double quantum coherence transfer
H Lei, J Peeling - Journal of Magnetic Resonance, 2000 - Elsevier
… simultaneous DQ editing for more than one metabolite is demonstrated, using a DQ filtering
sequence with a composite dual-band DQ coherence read pulse to edit … ) and glutathione (30…
sequence with a composite dual-band DQ coherence read pulse to edit … ) and glutathione (30…
A new strategy for in vivo spectral editing. Application to GABA editing using selective homonuclear polarization transfer spectroscopy
J Shen, J Yang, IY Choi, SS Li, Z Chen - Journal of magnetic resonance, 2004 - Elsevier
… creatine and glutathione while detecting the GABA-4 … an editing yield similar to that of
conventional editing methods. The NAA methyl group at 2.02 ppm was simultaneously detected …
conventional editing methods. The NAA methyl group at 2.02 ppm was simultaneously detected …
Frequency and phase correction for multiplexed edited MRS of GABA and glutathione
… FPC in both the γ-aminobutyric acid- and glutathione-edited spectra in the in vivo data. …
11-14, it is now possible to simultaneously edit multiple metabolites in a single acquisition …
11-14, it is now possible to simultaneously edit multiple metabolites in a single acquisition …
A cellulosic multi-bands fluorescence probe for rapid detection of pH and glutathione
S Xia, Y Duan, S Yu, Y Sun, H Zhu, Z Zhao… - Carbohydrate …, 2024 - Elsevier
… dual-spectral bands enable target analyte detection in the … detection of pH cannot provide
sufficient information about the cellular microenvironment, therefore simultaneous detection of …
sufficient information about the cellular microenvironment, therefore simultaneous detection of …
A lysosome-targetable fluorescent probe for simultaneous detection and discrimination of Cys/Hcy and GSH by dual channels
X Song, Y Tu, R Wang, S Pu - Dyes and Pigments, 2020 - Elsevier
… develop probes that can simultaneously distinguish Cys, Hcy … -O-NBD for simultaneous
detection and discrimination of Cys/… be used for simultaneous detection and discrimination of Cys/…
detection and discrimination of Cys/… be used for simultaneous detection and discrimination of Cys/…
Detection of an antioxidant profile in the human brain in vivo via double editing with MEGA‐PRESS
M Terpstra, M Marjanska, PG Henry… - … in Medicine: An …, 2006 - Wiley Online Library
… (DHA) and oxidized glutathione (GSSG) were measured at … Concurrent detection of
Asc and GSH was attempted via … spectral editing of GABA and taurine using double-banded …
Asc and GSH was attempted via … spectral editing of GABA and taurine using double-banded …
A novel selective probe for detecting glutathione from other biothiols based on the concept of fluorescence fusion
W Wang, K Wang, XT Wang, RJ Man, C Xu… - Analytica Chimica …, 2021 - Elsevier
… 3, we measured the absorption and fluorescence spectra of MZ-NBD towards Cys/Hcy and
GSH in PBS buffer (10 mM, 1% DMSO, pH 7.4). The UV absorption results (Fig. 3A) indicated …
GSH in PBS buffer (10 mM, 1% DMSO, pH 7.4). The UV absorption results (Fig. 3A) indicated …