Applications of transcranial Doppler in the ICU: a review
H White, B Venkatesh - Intensive care medicine, 2006 - Springer
… TCD monitoring in neurocritical care. Newer developments in this technology include venous
… [51] performed a systematic review comparing TCD with cerebral angiography to diagnose …
… [51] performed a systematic review comparing TCD with cerebral angiography to diagnose …
Transcranial Doppler monitoring in carotid endarterectomy: a systematic review and meta‐analysis
R Udesh, P Natarajan, K Thiagarajan… - … of Ultrasound in …, 2017 - Wiley Online Library
… efficacy of transcranial Doppler sonography in … systematically review the current scientific
literature to evaluate the diagnostic accuracy of intraoperative transcranial Doppler monitoring …
literature to evaluate the diagnostic accuracy of intraoperative transcranial Doppler monitoring …
[HTML][HTML] The role of transcranial doppler in traumatic brain injury: A systemic review and meta-analysis
… for all five studies: Patients with traumatic brain injury having abnormal and normal
transcranial Doppler monitoring. (Odds ratio of poor outcome: 3.87; 95% confidence interval: 2.97-…
transcranial Doppler monitoring. (Odds ratio of poor outcome: 3.87; 95% confidence interval: 2.97-…
Transcranial Doppler ultrasonography monitoring of cerebral hemodynamics during performance of cognitive tasks: a review
N Stroobant, G Vingerhoets - Neuropsychology review, 2000 - Springer
… the applications of transcranial Doppler (TCD) ultrasonography. The purpose of this review
is to … The first step of the literature analysis involved a systematic search of psychological and …
is to … The first step of the literature analysis involved a systematic search of psychological and …
The role of transcranial Doppler monitoring in patients with multi‐territory acute embolic strokes: a review
O Kargiotis, K Psychogios, A Safouris… - Journal of …, 2019 - Wiley Online Library
… Thus, TCD monitoring may potentially identify cases that will present with early recurrence. …
on TCD monitoring.35, 36 Moreover, a recent systematic review and meta-analysis found that …
on TCD monitoring.35, 36 Moreover, a recent systematic review and meta-analysis found that …
Advances in transcranial Doppler ultrasonography
G Tsivgoulis, AV Alexandrov, MA Sloan - Current neurology and …, 2009 - Springer
… at the bedside, and allows monitoring both in acute emergency … performance based on
literature analysis and extensive personal … monitored with 2-MHz transcranial doppler monitoring. …
literature analysis and extensive personal … monitored with 2-MHz transcranial doppler monitoring. …
Non-invasive brain stimulation in the modulation of cerebral blood flow after stroke: A systematic review of Transcranial Doppler studies
PC Iyer, S Madhavan - Clinical Neurophysiology, 2018 - Elsevier
… Transcranial Doppler (TCD), a clinically available non-invasive diagnostic tool, allows for
evaluation of … A systematic review of literature to understand the effects of NIBS on CBFv using …
evaluation of … A systematic review of literature to understand the effects of NIBS on CBFv using …
Cerebral blood flow during cardiopulmonary bypass in pediatric cardiac surgery: the role of transcranial Doppler–a systematic review of the literature
A Polito, Z Ricci, L Di Chiara, C Giorni… - Cardiovascular …, 2006 - Springer
… "trans cranial Doppler" crossed with "pediatric cardiac surgery" AND "cardio pulmonary by
pass", OR deep hypothermic cardiac arrest", OR "neurological monitoring"… transcranial doppler …
pass", OR deep hypothermic cardiac arrest", OR "neurological monitoring"… transcranial doppler …
Non-invasive monitoring of intracranial pressure using transcranial Doppler ultrasonography: is it possible?
… In conclusion, although Transcranial Doppler … to systematically compare them in different
clinical conditions, in order to determine which approach offers the best reliability to monitor ICP …
clinical conditions, in order to determine which approach offers the best reliability to monitor ICP …
Transcranial doppler
VK Sharma, KS Wong, AV Alexandrov - … , Diagnosis and Treatment, 2016 - karger.com
… monitor MES intra-operatively during carotid interventions and cardiac surgery [12–15] .
Continuous TCD monitoring … [38] systematically reviewed the accuracy of TCD, when compared …
Continuous TCD monitoring … [38] systematically reviewed the accuracy of TCD, when compared …
相关搜索
- transcranial doppler monitoring carotid endarterectomy
- cerebral transcranial doppler monitoring
- transcranial doppler monitoring stroke
- transcranial doppler monitoring carotid artery
- transcranial doppler monitoring subarachnoid hemorrhage
- transcranial doppler monitoring intraoperative
- transcranial doppler monitoring middle cerebral artery
- transcranial doppler monitoring angioplasty
- transcranial doppler monitoring stenting
- transcranial doppler monitoring microemboli
- transcranial doppler monitoring vasospasm
- bilateral transcranial doppler monitoring
- transcranial doppler monitoring cerebral blood flow
- transcranial doppler monitoring mes
- transcranial doppler monitoring recanalization
- transcranial doppler monitoring cerebral arteries