A fine time-resolution (≪ 3 ps-rms) time-to-digital converter for highly integrated designs
L Perktold, J Christiansen - 2013 IEEE International …, 2013 - ieeexplore.ieee.org
… To fully exploit the capabilities of such new sensors, time-to-… , time resolutions in the 1 ps
domain on a single channel have been achieved, [6] or [7]. At the level of a few ps resolution, …
domain on a single channel have been achieved, [6] or [7]. At the level of a few ps resolution, …
A multichannel time-to-digital converter ASIC with better than 3 ps RMS time resolution
L Perktold, J Christiansen - Journal of Instrumentation, 2014 - iopscience.iop.org
… time intensive task during production. A novel multipurpose TDC ASIC offering fine-time
resolution … In this contribution a fine-time resolution TDC precisely matched to requirements of …
resolution … In this contribution a fine-time resolution TDC precisely matched to requirements of …
A 16 channel high resolution (< 11 ps RMS) Time-to-Digital Converter in a Field Programmable Gate Array
C Ugur, E Bayer, N Kurz, M Traxler - Journal of Instrumentation, 2012 - iopscience.iop.org
… The time interval measurements are done using 2 channels. The time resolution of … of 10.3
ps RMS on two channels, yielding 7.3 ps RMS (10.3 ps/√2) on a single channel is achieved. …
ps RMS on two channels, yielding 7.3 ps RMS (10.3 ps/√2) on a single channel is achieved. …
A High-Resolution ( RMS) 48-Channel Time-to-Digital Converter (TDC) Implemented in a Field Programmable Gate Array (FPGA)
E Bayer, M Traxler - IEEE Transactions on nuclear science, 2011 - ieeexplore.ieee.org
… Time interval (TI) measurements between two channels were made to determine the
RMS and the time resolution of a single channel. At least 6 ps single channel resolution was …
RMS and the time resolution of a single channel. At least 6 ps single channel resolution was …
A 75 ps rms time resolution BiCMOS time to digital converter optimized for high rate imaging detectors
C Hervé, K Torki - Nuclear Instruments and Methods in Physics Research …, 2002 - Elsevier
… integrated time to digital converter (TDC) with a bin size adjustable in the range of 125 to 175
ps … Time measurements are extracted off chip at the maximum throughput of 40 MHz. The …
ps … Time measurements are extracted off chip at the maximum throughput of 40 MHz. The …
A multichannel high-resolution (< 5 ps RMS between two channels) Time-to-Digital Converter (TDC) implemented in a field programmable gate array (FPGA)
E Bayer, P Zipf, M Traxler - 2011 IEEE Nuclear Science …, 2011 - ieeexplore.ieee.org
… ps RMS TDC design [1] that uses dedicated carry-chains for time interpolation purposes and
is able to perform two time-… reaching a time resolution of 4 ps RMS between two channels. …
is able to perform two time-… reaching a time resolution of 4 ps RMS between two channels. …
A 128-channel, 710 M samples/second, and less than 10 ps RMS resolution time-to-digital converter implemented in a Kintex-7 FPGA
C Liu, Y Wang - IEEE Transactions on Nuclear Science, 2015 - ieeexplore.ieee.org
… The differential non-linearity and time resolution can be significantly improved by … time
of 1.47 ns, a dynamic range of 360 ns, and a root-mean-square resolution of less than 10 ps …
of 1.47 ns, a dynamic range of 360 ns, and a root-mean-square resolution of less than 10 ps …
A 2.3-ps RMS resolution time-to-digital converter implemented in a low-cost cyclone V FPGA
… The root mean square (rms) for the timing resolution measured … -time intervals (less than
1 ns) was 2.3 and 5.2 ps, respectively. A 14.1-ps rms timing resolution was measured at a time …
1 ns) was 2.3 and 5.2 ps, respectively. A 14.1-ps rms timing resolution was measured at a time …
A 4.2 ps time-interval RMS resolution time-to-digital converter using a bin decimation method in an UltraScale FPGA
Y Wang, C Liu - IEEE Transactions on Nuclear Science, 2016 - ieeexplore.ieee.org
… time intervals in the range from 0 to 440 ns, the average time-interval RMS resolution is
measured by the two TDCs with 4.2 ps… timestamp resolution of single TDC is derived as 2.97 ps. …
measured by the two TDCs with 4.2 ps… timestamp resolution of single TDC is derived as 2.97 ps. …
A compact system for high precision time measurements (< 14 ps RMS) and integrated data acquisition for a large number of channels
M Traxler, E Bayer, M Kajetanowicz… - Journal of …, 2011 - iopscience.iop.org
… include the limited time resolution of around 40 ps RMS, the … it possible to reach a time
resolution of < 10 ps for high-end … between resource usage and time-resolution. The specific …
resolution of < 10 ps for high-end … between resource usage and time-resolution. The specific …
相关搜索
- ps rms fine time resolution
- time resolution nuclear physics experiments
- time interval rms
- rms resolution real time temperature correction
- high resolution multihit time
- rms resolution cyclone v fpga
- ps resolution interpolation time
- time resolution polystyrene rms
- rms resolution interleaved sampling method
- temporal resolution ps rms
- time resolution power spectral density rms
- time resolution pmsm rms
- time resolution psrms
- time resolution ps rms fmri
- time resolution ps rms sensor